SpecificationBrand : wirenco
BulletPoint1 : Color of Wire May not be the Same as the Picture Shown.
BulletPoint2 : Has a Heat Capacity of 90 degreesC and is rated for 600-Volts, Has an Allowable Ampacity of 20 Amps
BulletPoint3 : Used Outdoors for Direct Earth Burial, Resistant to Sunlight and Moisture
BulletPoint4 : Used Indoors for Wet or Corrosive Locations
BulletPoint5 : #12 AWG Wire with 2 Annealed (Soft) Copper (Cu) Conductors
Color : Black
Color1 : Black
Color2 : White
ExternallyAssignedProductIdentifier1 : 850026183917
ExternallyAssignedProductIdentifier2 : 0850026183917
ExternallyAssignedProductIdentifier3 : 810102560254
ExternallyAssignedProductIdentifier4 : 0810102560254
ExternallyAssignedProductIdentifier5 : 0697273098850
ExternallyAssignedProductIdentifier6 : 0810102561381
ItemForm : Sheet
ItemName : Wirenco 12/2 UF-B Wire, Underground Feeder and Direct Earth Burial Cable (250Ft Cut)
ItemPackageDimensions_Height : 36.83 centimeters
ItemPackageDimensions_Length : 8.89 centimeters
ItemPackageDimensions_Width : 36.83 centimeters
ItemPackageQuantity : 1
ItemShape : 33 Ft Long
ItemTypeKeyword : electrical-wires
Manufacturer : wirenco
Material : Copper
ModelNumber : 14367-#
NumberOfItems : 1
NumberOfWires : 3
PartNumber : 14367-#
ProductDescription : p>
Applications:UF-B is an underground feeder and branch circuit wiring cable. It can be used as an underground feeder from an existing building to outdoor lighting fixtures, pumps, outbuildings and other equipment. Its applications are outlined in Article 340 NEC 2008 and NEC 2011. UF-B is rated at 600 volts. Although it is rated at a conductor temperature of 90ºC dry / wet, its ampacity is limited to 60ºC according to the NEC 2008 AND NEC 2011. UF-B may be directly buried or installed where exposed to sunlight. When used as an NM cable it must comply with the requirements in NEC 2008 and NEC 2011 Article 334.
Standards:
ASTM - B3 and B-8
UL Standard 83
UL Standard 493
Federal Specification A-A-59544
National Electrical Code, NFPA 70, 2011 Edition
RoHS/REACH
Construction:
Insulation: Polyvinyl Chloride (PVC) with a nylon covering. Color coded phase identification.
Jacket: Polyvinyl Chloride
PVC.
Specifications:
Size:12 AWG
Number of Conductors:2
PVC Insulation Thickness:0.030 inches
Ground Wire Size:12 AWG
Nylon Thickness:0.005 inches
Nominal Cable Dimensions:.463 inches x .183 inches
Weight per Foot: 0.95 lbs
Allowable Ampacity: 20 Amps
ProductSiteLaunchDate : 2021-01-25T16:00:00.000Z
Size : 250Ft Cut
Strands : Multi Strand
Style : 22/2
SupplierDeclaredDgHzRegulation : not_applicable
UnitCount : 250
Voltage : 600 volts