Nassau Electrical Supply 300' 6-6-6 Erskine Aluminum URD Triplex Direct Burial

Imported from USA | Ships in 10 working days

5% instant discount on non COD

1

₹ 81100/-

The price at cart2india.com is inclusive of custom duties, GST, freight forwarding and other charges.

Free Shipping across India. Powered by BlueDart

Product Information


Specification
Brand : Nassau Electrical Supply
BulletPoint1 : Size AWG: 6
BulletPoint2 : Number of Strands: 7
BulletPoint3 : Insulation Thickness (inches): 0.060
BulletPoint4 : Outside Diameter (inches): 0.640
BulletPoint5 : Weight (Lbs/1000ft): 145
Color : Black
ConnectorType : Screw
ExternallyAssignedProductIdentifier1 : 782321856329
ExternallyAssignedProductIdentifier2 : 0782321856329
ExternallyAssignedProductIdentifier3 : 00013964851205
IncludedComponents : black SOOW cable
ItemName : Nassau Electrical Supply 300' 6-6-6 Erskine Aluminum URD Triplex Direct Burial
ItemPackageDimensions_Height : 24.4094 centimeters
ItemPackageDimensions_Length : 5.207 centimeters
ItemPackageDimensions_Width : 24.2062 centimeters
ItemPackageQuantity : 1
ItemShape : Round
ItemTypeKeyword : electrical-wires
Manufacturer : Nassau
Material : polyethylene
MaximumVoltage : 300 volts
MeasurementSystem : Imperial
ModelNumber : Eagles
NumberOfItems : 1
NumberOfWires : 3
OperatingVoltage : 300 volts
PackageLevel : unit
PartNumber : 1
ProductDescription : Applications Directly buried or installed inducts for 600 volt secondary distribution. Construction Concentric stranded or compressed 1350-H19 aluminum conductors, crosslinked polyethylene insulation. Insulated conductors surface printed, neutral triple yellow striped. Two phase and one neutral conductor twisted together (LH lay) or parallel if so specified. Black neutrals may be specified if desired. Standards Secondary UD triplex conductor 600V cable meets or exceeds the following ASTM specifications. B-230 Aluminum Wire, 1350-H19 for Electrical Purposes. B-231 Aluminum 1350 conductors, Concentric-Lay-Stranded. B-786 "19 Wire combination unilay-stranded Aluminum Conductors for subsequent insulation". B-901 "Compressed round stranded Aluminum Conductors using single input wire construction". Secondary UD triplex conductor 600V cable meets or exceeds all applicable requirements of ICEA S-105-692. "USE-2" per UL 854 available upon request. Options Cable in Duct (CIC) Abrasion Resistant Ampacity 90oC conductor temperature, 20oC ambient, RHO 50, 100% load factor for three conductor triplex with neutral carrying only unbalanced load. Technical data for cable with solid black neutral is identical to yellow extruded stripe data. All yellow extruded stripe cable is XLP insulation. To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition. Specifications Code Name Erksine Phase Conductor Size AWG 6 Phase Conductor Stranding 7/w Phase Conductor Insulation Thickness 60 mls Neutral Size AWG 6 Neutral Stranding 7/w Neutral Insulation Thickness 60 mls Single Phase Conductor .299 Inches Outside Diameter .646 Inches Weight Per 1000ft 143 Lbs Ampacity Direct Burial 95 Amps Ampacity In Duct 70 Amps. Images are for reference only See Product Specifications. Please order careful no returns accepted.
ProductSiteLaunchDate : 2013-09-04T13:54:22.967Z
Size : 300FT
SpecificationMet : UL
Strands : Multi Strand
Style : 18 Gauge
SupplierDeclaredDgHzRegulation : not_applicable
SupplierDeclaredDgHzRegulation1 : not_applicable
SupplierDeclaredDgHzRegulation2 : not_applicable
SupplierDeclaredDgHzRegulation3 : not_applicable
SupplierDeclaredDgHzRegulation4 : not_applicable
SupplierDeclaredDgHzRegulation5 : not_applicable
SupplierDeclaredHasProductIdentifierExemption : 1
TemperatureRating : 221 degree fahrenheit
TerminalType : Screw Terminal
UnitCount : 1
UnspscCode : 26121629
Voltage : 600 volts