SpecificationBrand : Stock Wire
BulletPoint1 : #6 AWG Wire with Annealed (Soft) Copper (Cu) Conductors
BulletPoint2 : Used Indoor for Wet or Corrosive Locations, Resistant to Light and Moisture
BulletPoint3 : Used Outdoors for Direct Earth Burial, Resistant to Sunlight and Moisture
BulletPoint4 : Has a Heat Capacity of 90 degrees Celsius and is rated for 600-Volts, Has an Allowable Ampacity of 55 Amps
BulletPoint5 : Color of Wire May not be the Same as the Picture Shown.
Color : Gray
ConnectorType : Twist
CustomerPackageType : Standard Packaging
ExternallyAssignedProductIdentifier1 : 680226296977
ExternallyAssignedProductIdentifier2 : 0680226296977
ExternallyAssignedProductIdentifier3 : 00032886918339
FinishType : Polished
GpsrSafetyAttestation : 1
IncludedComponents : 250Ft Wire Coil
ItemDisplayDimensions_Length : 100 centimeters
ItemDisplayWeight : 0.05 pounds
ItemForm : Coil
ItemName : 6/3 UF-B Wire, Underground Feeder and Direct Earth Burial Cable (125ft)
ItemPackageDimensions_Height : 50.8 centimeters
ItemPackageDimensions_Length : 15.24 centimeters
ItemPackageDimensions_Width : 50.8 centimeters
ItemPackageQuantity : 1
ItemShape : Round Rod
ItemTypeKeyword : electrical-wires
Manufacturer : Stock Wire
Material : Polyvinyl Chloride
MaximumVoltage : 10 volts
MeasurementSystem : Metric
ModelNumber : 6124
NumberOfItems : 1
NumberOfWires : 4
OperatingVoltage : 240 volts
PackageLevel : unit
PartNumber : 21687
ProductDescription :
Applications:
UF-B is an underground feeder and branch circuit wiring cable. It can be used as an underground feeder from an existing building to outdoor lighting fixtures, pumps, outbuildings and other equipment. Its applications are outlined in Article 340 NEC 2008 and NEC 2011. UF-B is rated at 600 volts. Although it is rated at a conductor temperature of 90ºC dry / wet, its ampacity is limited to 60ºC according to the NEC 2008 AND NEC 2011. UF-B may be directly buried or installed where exposed to sunlight. When used as an NM cable it must comply with the requirements in NEC 2008 and NEC 2011 Article 334.
Standards:
ASTM - B3 and B-8
UL Standard 83
UL Standard 493
Federal Specification A-A-59544
National Electrical Code, NFPA 70, 2011 Edition
RoHS/REACH
Construction:
Insulation: Polyvinyl Chloride (PVC) with a nylon covering. Color coded phase identification.
Jacket:Sunlight and moisture resistant gray PVC.
Specifications:
Size:6 AWG
Number of Conductors:3
PVC Insulation Thickness:0.035 inches
Ground Wire Size:10 AWG
Nylon Thickness:0.005 inches
Nominal Cable Dimensions:1.223 inches x .361 inches
Weight per Foot: 0.437 lbs
Allowable Ampacity: 55 Amps
ProductSiteLaunchDate : 2017-12-04T08:00:00.000Z
Size : 125ft
SpecificationMet : UL
Strands : Multi Strand
SupplierDeclaredDgHzRegulation : not_applicable
TemperatureRating : 1000 deg F (538 deg C)
TensileStrength : 35000 pounds_per_square_inch
TerminalType : Screw Terminal
UnitCount : 125
UnspscCode : 39121400
Voltage : 600 volts