Specification Brand : Stock Wire BulletPoint1 : Branch, feeder or service power distribution in commercial, industrial, institutional and multi-residential buildings. Lighting, power, control and signal circuits BulletPoint2 : Voltage rating for all applications is not to exceed 600 Volts BulletPoint3 : Type MC cables are constructed of soft-drawn bare copper (Solid or Stranded) with lead-free THHN/THWN-2 rated at 90˚C dry BulletPoint4 : The conductors are cabled, wrapped completely in a Mylar binder tape with an aluminum tape interlocked sheath applied over the entire assembly BulletPoint5 : UL 83, UL 1569, UL 1581 and UL 2556 Rated Color : Metallic ExternallyAssignedProductIdentifier : 00850052073749 ExternallyAssignedProductIdentifier1 : 697273099338 ExternallyAssignedProductIdentifier2 : 0697273099338 IncludedComponents : Wire ItemName : 4/3 Metal Clad (MC) Cable with Ground, Aluminum Armored, Stranded Copper Conductors (25FT Cut) ItemPackageDimensions_Height : 3 inches ItemPackageDimensions_Length : 9 inches ItemPackageDimensions_Width : 9 inches ItemPackageQuantity : 1 ItemTypeKeyword : electrical-wires Manufacturer : Stock Wire Material1 : Aluminum Material2 : Copper ModelNumber : 18782 NumberOfItems : 1 NumberOfWires : 4 PartNumber : 18782 ProductDescription : Applications:Branch, feeder or service power distribution in commercial, industrial, institutional and multi-residential buildings. Lighting, power, control and signal circuits. Fished or embedded in plaster, concealed or exposed installations. Environmental air handling spaces per NEC 300.22 (C). Places of assembly and theaters. Under raised floors for technology equipment conductors and cables. Installation in cable tray and approved raceways. Class I Div.2, Class II Div.2, Class III Div. 1 Hazardous Locations. Voltage rating for all applications is not to exceed 600 Volts.Standards:- ASTM B-3, B-8 and B-787- UL 83, UL 1569, UL 1581 and UL 2556- NEC 2014 : 300.22 (C), 310.10, 330,392, 518, 520, 530, 645- NFPA 70- Federal Specification A-A59544- IEEE 1202 (70,000 BTU/hr) Vertical Flame Test/FT4- CT Rated for 600 Volts if installed per the NEC directives- Rated for 1 and 2 hour Through Penetration- RoHS Compliant- ARRA 2009 Buy American CompliantSpecifications:Conductors: 3 + 1 Ground (4 total)Size: 4 AWGGround Size: 8 AWGOutside Diameter: 0.941 inchesWeight: 0.674 / footAmpere Rating: 70 Amps at 60 Celcius, 85 Amps at 75 Celcius and 95 Amps at 90 Celcius ProductSiteLaunchDate : 2021-12-16T16:00:00.000Z Size : 25FT Cut Strands : Multi Strand SupplierDeclaredDgHzRegulation : not_applicable SupplierDeclaredHasProductIdentifierExemption : 1 UnitCount : 1 UnspscCode : 26121600 Voltage : 600 volts