SpecificationBrand : Stock Wire
BulletPoint1 : #4 AWG Commercial Wiring for Outlets, Switches and Other Loads
BulletPoint2 : Contains Copper (Cu) Conductors Made with Annealed (Soft), Compressed Copper
BulletPoint3 : Can be Used in Wet or Dry Locations. Insulation is High Heat and Moisture Resistant Polyvinyl Chloride (PVC). Jacket is Abrasion, Moisture, Gasoline, and Oil Resistant Nylon
BulletPoint4 : Has an Allowable Ampacity of: 70 Amps at 60 Degrees Celsius, 85 Amps at 75 Degrees Celsius, and 95 Amps at 90 degrees Celsius
BulletPoint5 : Rated for 600-Volts with a Heat Capacity of up to 90 Degrees Celsius.
BulletPoint6 : Guarantee: Our outdoor waterproof electrical connectors provide a more competitive and distinctive effect than others. It is a high-quality waterproof wire connector. Changing small tools will lead you to prevent further disasters. Choose the extra safe waterproof wire connector for sprinkler wiring and outdoor landscape light wiring.
Color : White
ConnectorType : Twist
ExternallyAssignedProductIdentifier1 : 680226295949
ExternallyAssignedProductIdentifier2 : 0680226295949
ItemName : 4 AWG 19-Stranded THHN White Copper Building Wire (100ft Cut)
ItemPackageDimensions_Height : 36.4998 centimeters
ItemPackageDimensions_Length : 17.1958 centimeters
ItemPackageDimensions_Width : 35.5092 centimeters
ItemTypeKeyword : electrical-wires
LowerTemperatureRating : -40 degrees_celsius
Manufacturer : Stock Wire
Material : Polyvinyl Chloride
MaximumVoltage : 300 volts
ModelNumber : 22012-1000
NumberOfItems : 1
NumberOfWires : 12
PartNumber : THHN4WHITE
ProductDescription :
Applications:
Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC). 4 AWG THHN-THWN-2 is permitted for new construction or rewiring for 600-volt applications. Applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90°C or not to exceed 75°C in oil or coolants. Applications requiring Type MTW conductor is appropriate for use in dry locations at 90°C, or not to exceed 60°C in wet locations or where exposed to oils or coolants. Applications requiring Type AWM conductor is appropriate for use at temperatures to not exceed 105°C in dry locations.
Also Known As:
4 AWG Copper wire, 4 AWG THWN-2, 4 AWG Building Wire, hook up wire, conduit wire, lighting wire, nylon copper wire, construction cable, 4 Gauge Wire.
Features
Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG. All sizes are rated gasoline and oil-resistant II.
Jacket:
A tough, polyamide, Nylon outer covering per UL-1063 and UL-83.
Standards:
Underwriters Laboratories Standards UL-83, UL-1063, UL-758
AWM Spec 1316, 1317, 1318, 1319, 1320, 1321
ASTM Stranding Class B3, B8, B787
Federal Specification A-A-59544
NEMA WC70/ICEA S-95-658
Institute of Electrical and Electronics Engineers
Constrction:
Insulation:Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-8
Specifications:
Size:4 AWG
Number of Strands:19
PVC Insulation Thickness (Conductor):1.020 mm / 0.040 inches
Nylon Jacket Thickness:0.150 mm / 0.317 inches
Outside Diameter:8.06 mm / 0.317 inches
Weight per Foot: 0.166 lbs
Allowable Ampacity:70 Amps at 60℃ / 85 Amps at 75℃ / 95 Amps at 90℃
ProductSiteLaunchDate : 2018-05-02T21:00:00.000Z
Size : 100ft cut
Strands : 19
SupplierDeclaredDgHzRegulation : not_applicable
SupplierDeclaredHasProductIdentifierExemption : 1
TemperatureRating : 105 degree celsius
TerminalType : Heat Shrink Tube
UnitCount : 1
Voltage : 600 volts
Wattage : 300