SpecificationBrand : Stock Wire
BulletPoint1 : #12 AWG Wire with 2 Annealed (Soft) Copper (Cu) Conductors
BulletPoint2 : Used Indoors for Wet or Corrosive Locations, Resistant to Light and Moisture
BulletPoint3 : Used Outdoors for Direct Earth Burial, Resistant to Sunlight and Moisture
BulletPoint4 : Has a Heat Capacity of 90 degreesC and is rated for 600-Volts, Has an Allowable Ampacity of 20 Amps
BulletPoint5 : Color of Wire May not be the Same as the Picture Shown.
Color : Gray
ExternallyAssignedProductIdentifier1 : 682550997216
ExternallyAssignedProductIdentifier10 : 00032886954207
ExternallyAssignedProductIdentifier2 : 0682550997216
ExternallyAssignedProductIdentifier3 : 079407992089
ExternallyAssignedProductIdentifier4 : 032886954207
ExternallyAssignedProductIdentifier5 : 0032886954207
ExternallyAssignedProductIdentifier6 : 0767654231197
ExternallyAssignedProductIdentifier7 : 0085407314110
ExternallyAssignedProductIdentifier8 : 0079407992089
ExternallyAssignedProductIdentifier9 : 00085407314110
FinishType : Polished
Hazmat : 32000000
ItemDisplayWeight : 0.3 pounds
ItemForm : Coil
ItemName : 12/2 UF-B Wire, Underground Feeder and Direct Earth Burial Cable (45ft)
ItemPackageDimensions_Height : 36.4998 centimeters
ItemPackageDimensions_Length : 9.6012 centimeters
ItemPackageDimensions_Width : 36.3982 centimeters
ItemPackageQuantity : 1
ItemShape : Wire
ItemTypeKeyword : electrical-wires
Manufacturer : Stock Wire
Material : Polyvinyl Chloride
ModelNumber : mea220610ee0410
NumberOfItems : 1
NumberOfWires : 2
PackageLevel : unit
PartNumber : 14367
ProductDescription :
Applications:
UF-B is an underground feeder and branch circuit wiring cable. It can be used as an underground feeder from an existing building to outdoor lighting fixtures, pumps, outbuildings and other equipment. Its applications are outlined in Article 340 NEC 2008 and NEC 2011. UF-B is rated at 600 volts. Although it is rated at a conductor temperature of 90ºC dry / wet, its ampacity is limited to 60ºC according to the NEC 2008 AND NEC 2011. UF-B may be directly buried or installed where exposed to sunlight. When used as an NM cable it must comply with the requirements in NEC 2008 and NEC 2011 Article 334.
Standards:
ASTM - B3 and B-8
UL Standard 83
UL Standard 493
Federal Specification A-A-59544
National Electrical Code, NFPA 70, 2011 Edition
RoHS/REACH
Construction:
Insulation: Polyvinyl Chloride (PVC) with a nylon covering. Color coded phase identification.
Jacket:Sunlight and moisture resistant gray PVC.
Specifications:
Size:12 AWG
Number of Conductors:2
PVC Insulation Thickness:0.030 inches
Ground Wire Size:12 AWG
Nylon Thickness:0.005 inches
Nominal Cable Dimensions:.463 inches x .183 inches
Weight per Foot: 0.95 lbs
Allowable Ampacity: 20 Amps
ProductSiteLaunchDate : 2017-11-22T16:00:00.000Z
RecommendedUsesForProduct : Various bulbs, pendant lights, fans, household appliances, advertisement board LED lamp wire, audio cable speaker line, and DIY projects
Size : 45ft
Strands : Multi Strand
Style : 2 Conductor
SupplierDeclaredDgHzRegulation : not_applicable
UnitCount : 45
Voltage : 600 volts