Digital Rotary Viscometer, 40.2KU-141.0 KU 500ML 220V 10W Rotary Viscometer Viscosity Tester Digital Viscometer Paint Viscosity for KU Value, CP (Centipoise), G (Gram), Room Temperature

Imported from USA | Ships in 10 working days

5% instant discount on non COD

1

₹ 101500/-

The price at cart2india.com is inclusive of custom duties, GST, freight forwarding and other charges.

Free Shipping across India. Powered by BlueDart

Product Information


Specification
Brand : GOSHET
BulletPoint1 : 【Technical parameters】:Measuring range:40.2KU-141.0 KU value 32g-1099g(load value),27 cp-5250cp; Measuring accuracy:1.5% of full scale; Measuring repeatability:1.5% of full scale; Stirring shaft rotating speed:200r/min±1r/min; Container capacity:about 500ml; Input voltage:220V50HZ.
BulletPoint2 : 【Microcomputer】:The stirring blade is driven by a special constant speed motor and rotates at 200r/min. The resistance torque of the rotating stirring blades in the sample being tested is converted by the computer to KU value (Krebs Krebs) units (KU) to get the 200a logarithmic function of the load required for r/min rotation speed, which is generally used to indicate the viscosity for brushing and rolling).
BulletPoint3 : 【Operation】:the operator only needs to insert the stirring blade into the sample to be measured to the specified depth, can be read directly from the instrument corresponding to the KU value of the sample, CP (centipoise) g (grams).
BulletPoint4 : 【Usage】:It is used to determine the viscosity of paints and other paints with KU value. The instrument can simultaneously display the KU value, CP (centipoise), g (grams) and room temperature of the viscosity of the sample under test.
BulletPoint5 : 【Note】:This instrument is a special instrument, if you have specialized personnel, please do not disassemble the instrument's shell, so as not to affect the measurement accuracy of the instrument. When the instrument is not in use for a while, the lifting handle of the instrument should be kept on the upper limit device and should not be placed in a lower position, otherwise it may cause inflexible lifting.
ExternallyAssignedProductIdentifier1 : 0756804654702
ExternallyAssignedProductIdentifier2 : 756804654702
IncludedComponents : 1*Stormer host 1*paddle 1*Measuring cup 1*Instruction 1*Certificate
ItemName : Digital Rotary Viscometer, 40.2KU-141.0 KU 500ML 220V 10W Rotary Viscometer Viscosity Tester Digital Viscometer Paint Viscosity for KU Value, CP (Centipoise), G (Gram), Room Temperature
ItemPackageDimensions_Height : 9 inches
ItemPackageDimensions_Length : 19.99 inches
ItemPackageDimensions_Width : 9 inches
ItemPackageQuantity : 1
ItemTypeKeyword : science-lab-viscometers
Manufacturer : Gdrockpond
ModelNumber : style
NumberOfItems : 1
PartNumber : sadassdcasd0
ProductDescription :

description:


technical parameter

Measuring range: 40.2KU-141.0 KU (KU) value 32g-1099g (load value), 27 cp-5250cp

Measurement accuracy: 1.5% of full scale

Measurement repeatability: 1.5% of full scale

The stirring shaft speed: 200 r/min±1 r/min

Container capacity: about 500ml

Input voltage: 220V50HZ

Power: 10W

Dimensions: 500mm*210mm*180mm(19.7*8.27*7.09in)

Weight: 8.5kg


Operation and use:

1.     Take the instrument out of the box and place it on the workbench.

2.     Take out the stirring blade from the packaging box, insert it into the sleeve of the rotating shaft according to the outline drawing, and fix it with the jacking screw.     Note that the jacking screw should be on the flat opening of the stirring blade.

3.     Plug in the power plug and turn it on without the power switch, the LCD will display the KU value, and the ¢ g reading is zero.

4.     Put the sample to be tested into the container that comes with the instrument, and the liquid level is about 10mm away from the container mouth.

5.     Place the container with the sample to be tested on the container base, press down the lifting handle, and immerse the stirring blade in the sample to be tested, and the mark on the shaft of the stirring blade is flush with the liquid surface.     The instrument automatically starts to run.

6.     After a few seconds, the display will display the KU value of the sample to be tested, CP (centipoise) g (gram) (the sample to be tested must be stirred for a few seconds to achieve uniformity, that is, dynamic equilibrium, the data displayed at this time is accurate)

7.     After the measurement is over, raise the lifting handle to a high place, and there is a limit device near the highest position, which can keep the instrument in this position.     The instrument stops rotating and enters the standby state again.


Package includes:

1*Stormer host

1*paddle

1*Measuring cup

1*Instruction

1*Certificate


ProductSiteLaunchDate : 2024-07-01T09:29:16.954Z
SupplierDeclaredDgHzRegulation : not_applicable