Taidacent Inverter Frequency Tachometer Line Speed Meter 0-10V Display 0-4-20mA Meter 4848MM 9999RPM Digital RPM Meter for Motor (DC0-20mA 0-9999M/Min)

Imported from USA | Ships in 10 working days

5% instant discount on non COD

1

₹ 9500/-

The price at cart2india.com is inclusive of custom duties, GST, freight forwarding and other charges.

Free Shipping across India. Powered by BlueDart

Product Information


Specification
Brand : Taidacent
BulletPoint1 : Current: 0.5 level
BulletPoint2 : Rated current: AC1A. AC5A, DC 20mA, DC 1A, DC 5A, DC 75mV Overload: 1. 2 times (continuous), 10 times/5 seconds (instantaneous)
BulletPoint3 : Power consumption: <0.4VA/phase
BulletPoint4 : Impedance: <20mΩ
BulletPoint5 : Frequency: 45~65Hz or DC
ExternallyAssignedProductIdentifier1 : 0739319149437
ExternallyAssignedProductIdentifier2 : 739319149437
FinishType : Finish
IncludedComponents : inc
ItemName : Taidacent Inverter Frequency Tachometer Line Speed Meter 0-10V Display 0-4-20mA Meter 4848MM 9999RPM Digital RPM Meter for Motor (DC0-20mA 0-9999M/Min)
ItemPackageQuantity : 1
ItemTypeKeyword : industrial-tachometers
Manufacturer : Taida
Material : Plastic
PartNumber : ZC-Invertertachometer-210706
PowerSourceType : PowerSource
ProductDescription : Parameter
Measurement accuracy
Current: 0.5 level
Signal input
Wiring: Simplex
Rated current: AC1A. AC5A, DC 20mA, DC 1A, DC 5A, DC 75mV Overload: 1. 2 times (continuous), 10 times/5 seconds (instantaneous)
Power consumption: <0.4VA/phase
Impedance: <20mΩ
Frequency: 45~65Hz or DC
Auxiliary power
The scope of work: AC/DC 80V~270V. AC220V. AC380V. AC100V. DC48V. DC24V
Power consumption: <4VA
Functional module
Communication Interface: 1 channel RS-485 communication, Modbus-RTU protocol
Baud rate: 1200~9600bps, default 2400 bps
Switch input: Support 2 dry node input
Switch output: Support 2 relay outputs, capacity: AC 250V/5A, DC 30V5A
Transmission output: Support 1 analog output: 0/4~20mA or 0~5/10V
Surroundings
Operating temperature: -10°C~+55°C
Storage temperature: -25°C~+70°C
Relative humidity: ≤93%, no corrosive gas place
Altitude: ≤2500m
Safety
Insulation resistance: >100MΩ
AC withstand voltage: AC 2KV
EMC performance
Electrostatic discharge: level 4
Electrical fast transient burst: level 4
Electrical fast transient burst: level 4
Dimensions
Frame size (mm): 120x120; 80x80; 96x48; 96x96; 80x80; 48x48; 120x60; 160x80
Hole size (mm): 111x111; 76x76; 92x45; 92x92; 68*68; 45x45; 114x56; 152x76
Note
1. In the input state of CT value and PT value, the "SET" key is the key to move the cursor to the right. AC current CT value:
CT = primary current value of current transformer/secondary current value of current transformer
DC current CT value:
CT=shunt primary current value/5 (signal input DC75mV)
CT=display value/1 (signal input DC 20mA, DC 4-20mA)
AC voltage PT value:
PT=Primary voltage value of voltage transformer/Secondary voltage value of voltage transformer
DC voltage PT value: PT=display value/input value

ProductSiteLaunchDate : 2021-07-06T10:27:22.340Z
Style : DC0-20mA 0-9999M/Min
UnspscCode : 41110000

Questions & Answers

Have a question? Ask experts

?
No question found

Ratings & Review

Rating Breakdown (average)

5*
0
4*
0
3*
0
2*
0
1*
0

No reviews found.

Have an opinion on this page? Let's hear it.