Specification Brand : NXUTKBNK BulletPoint1 : Industrial Power Supply BulletPoint2 : HLG-100H-36 100W waterproof LED power supply for PFC street lights Color : One Color ExternallyAssignedProductIdentifier : 6411587338679 ItemName : NXUTKBNK HLG-100H-36 100W Waterproof LED Power Supply for PFC Street Lights ItemPackageDimensions_Height : 1 centimeters ItemPackageDimensions_Length : 1 centimeters ItemPackageDimensions_Width : 1 centimeters ItemPackageQuantity : 1 ItemTypeKeyword : commercial-street-and-area-lighting Manufacturer : NXUTKBNK ModelNumber : NXUTKBNK NumberOfBoxes : 1 NumberOfItems : 1 PartNumber : NXUTKBNK ProductDescription : Industrial Power Supply HLG-100H-36 100W waterproof LED power supply for PFC street lights Model: HLG-100H-36 Work efficiency: 93 Output voltage accuracy: ±1 Power supply type: switching power supply Full range AC input voltage (up to 305VAC) Built-in active PFC (power factor correction) function, when the load is greater than or equal to 60%, the power factor is >0.9 Efficiency up to 93% Fully enclosed aluminum alloy shell with glue potting With short circuit protection/over current protection/over voltage protection/over heat protection Class 2 power supply unit, passed LPS (limited power supply) test Constant voltage + constant current working mode DC output range 36V, 0~2.65A Constant current voltage range 60% ~ 100% set voltage Output voltage accuracy ±1% Ripple and noise 200mVp-p Efficiency 93% Input voltage range 90~305VAC/127~431VDC Input surge current cold start, 60A/230V Voltage setting range 38~46V (Type A only, adjusted through VoADJ) Current setting range 1.4~2.28A (Type A only, adjusted through IoADJ) <;0.75mA/240VAC When the over-current protection output current reaches 95% to 108% of the set current, the constant current limit will resume. When the over-voltage protection output is 47~53V, the output voltage is shut down and restored or restarted. Overheating protection: shuts off the output voltage at 100℃±10℃ (RTH2) and recovers after cooling down Start-up rising holding time: 2500mA, 50mA, 16mA/230VAC/115VAC at full load; Type B: 2500mA, 200mA, 16mA Insulation characteristics: between input terminal and output terminal: 3.75KVAC, between input terminal and shell: 2KVAC, between output terminal and shell: 0.5KVAC, Operating temperature -40~+70℃ (see output load derating curve) Vibration resistance 10~500Hz, 5G12 minutes/cycle, XYZ each axis 72 minutes each Mean time between failures ≥ 192,200 hours, MIL-HDBK-217F (25℃)