Description:
New and
Made of high-quality materials,
1 pair of fiber electrode 3/5/7 fusion splicer for IFS-15 IFS-15H IFS-10 view
Installation and maintenance
Type: optical fiber electrode
View 3, View 5, View 7
Discharge time: 3000 times
Electrode replacement :
Fir st of all, make sure that the welding machine is closed.
Remove and release the protective cover of the electrode compartment.
Fix the upper electrode and remove the upper electrode. Then release the top.
Connect the lower electrode and remove the lower electrode.
Next, install a new electrode. The steps are reversed to the following
Remove the electrode. You can do it inside. The difference between the two
Both electrode tips must be 2.6 +/- 0.2 mm.
Finally, do not touch the tip of the electrode during the assembly process.
Prevent electrode damage and avoid electrode damage
Fall into the machine. After replacing the electrode, the position should be
Calibration.
Electrode cleaning and
calibration:
After installing the electrode, turn on the power switch of the welding machine.
Implementation.
After the welding machine enters the initial screen, press the menu key to enter the first-level menu.
Move the cursor to find the machine repairman and input the cleaning electrode.
After confirmation, the machine will automatically discharge and clean the aging electrodes.
Install the cut left and right optical fiber, move the optical fiber to find the curved position cursor, and maintain the position between the three-point and the single-wire optics.
The tip of the fiber and two electrodes pass through. The discharge test will be carried out by the machine and can be adjusted according to the actual situation.
Finally, press the menu key to exit.
Package Included:
1 pair * optical fiber electrode