Specification Brand : DONGKER BulletPoint1 : ★Battery charge and discharge intelligent control;You can set the charge and discharge time; BulletPoint2 : ★With serial communication function, real-time monitoring of the working status of the relay through the serial port; BulletPoint3 : ★Additional signal output, when the relay to meet the conditions, the output high, you can control other equipment. BulletPoint4 : ★A key emergency stop function (STOP button), with reverse protection, reverse does not burn. BulletPoint5 : ★SHOP WITH CONFIDENCE: To Provide You With the Highest Quality Service, If You Have Any Question, Please Feel Free to Contact Us.We Will Provide After-sales Service Until You Are Satisfied. CurrentRating : 20 amps ExternallyAssignedProductIdentifier1 : 0717066169724 ExternallyAssignedProductIdentifier2 : 717066169724 ItemName : Charge Discharge Integrated Module, XY-DJ DC 6-40V Battery Charging Boost Power Protection Board Module Over Discharge Protection Module With Cemory Function ItemPackageDimensions_Height : 11.4 centimeters ItemPackageDimensions_Length : 1.6 centimeters ItemPackageDimensions_Width : 6.3 centimeters ItemPackageQuantity : 1 ItemTypeKeyword : solid-state-relays Manufacturer : DONGKER Material : Other MaximumSwitchingCurrent : 20 amps MeasurementSystem : Imperial ModelNumber : FBM0-AAQ-12325 OperationMode : Automatic PartNumber : FBM0-AAQ-12325 ProductDescription : Module Highlights: 1. Battery charge and discharge intelligent control; 2. You can set the charge and discharge time; 3. With serial communication function, real-time monitoring of the working status of the relay through the serial port; 4. Additional signal output, when the relay to meet the conditions, the output high, you can control other equipment. 5. A key emergency stop function (STOP button), with reverse protection, reverse does not burn.
Operating mode: U-1: Charging measurement: When the measured voltage is lower than the lower limit voltage, the relay pulls above; the upper limit voltage, the relay is disconnected. U-2: charge measurement time control: set the charging time (OP); when the measured voltage is lower than the lower limit voltage, the relay pull, and then start the countdown OP time, the end of the timer, the relay off; when the measured voltage is higher than the upper limit voltage , The relay is disconnected. U-3: Discharge detection: When the measured voltage is lower than the lower limit voltage, the relay is off, above the upper limit voltage, the relay pulls; U-4: discharge detection time control: set the discharge time (OP); when the measured voltage is higher than the upper limit voltage, the relay pull, and then start the countdown OP time, the end of the timer, the relay off; when the measured voltage below the lower limit voltage , The relay is disconnected; U-5: voltage in the range, the relay pull: when the measured voltage between the upper and lower limits, the relay pull, the other circumstances open; U-6: voltage outside the interval, the relay pull: the measured voltage below the lower limit voltage or higher than the upper limit voltage, the relay pull, the other case the relay is off. ProductSiteLaunchDate : 2020-04-16T22:13:14.239Z SpecificationMet : Electromagnetic Compatibility SupplierDeclaredDgHzRegulation : not_applicable UnspscCode : 26111700 Voltage : 1 volts