SpecificationBrand : AITRIP
BulletPoint1 : Scope of application:PM2.5 Detector;Purifier;Air Exchangers;Filtering system
BulletPoint2 : Accurate and Reliable: detection, stable, good consistency;Quick response: response time is less than 10 seconds when the scene changes.
BulletPoint3 : Easy integration: UART output (or IO output can be customized), fan built-in;High resolution: resolution of 0.3ug/m3
BulletPoint4 : The SDS011 using principle of scattering,can get the particle concentration between 0.3 to 10um in the air.It with digital output and built-in fan is stable and reliable.
BulletPoint5 : Working principle:Using scattering principle:Light scattering can be induced when particles go through the detecting area;The scattered light is transformed into electrical signals and these signals will be amplified and processed PM sensor SDS011 High precision laser pm2.5 air quality detection sensor module Super dust dust sensors, digital output Note : It supports 5V power supply voltage, output signal TTL Is 5V, higher than this voltage, the product will burn out
Color : Blue
ConnectivityProtocol : Infrared
ConnectorType : Screw
ControlMethod : remote
CurrentRating : 5 amps
CustomerPackageType : Standard Packaging
ExternallyAssignedProductIdentifier1 : 701715454378
ExternallyAssignedProductIdentifier2 : 0701715454378
ExternallyAssignedProductIdentifier3 : 00700724295538
IncludedComponents : Touch Sensor Circuit Board
InternationalProtectionRating : IP54
ItemName : AITRIP PM Sensor SDS011 High Precision PM2.5 Air Quality Detection Sensor Module Super Dust Sensors Digital Output Compatible with Arduino
ItemPackageDimensions_Height : 13.9954 centimeters
ItemPackageDimensions_Length : 3.2004 centimeters
ItemPackageDimensions_Width : 9.2964 centimeters
ItemPackageQuantity : 1
ItemTypeKeyword : sensor-blocks
Manufacturer : AITRIP
Material : Copper
MaximumSupplyVoltage : 5 volts
MeasuringRange : 0.3 to 10 µm
ModelNumber : PM Sensor SDS011
MountingType : PCB Mount
NumberOfItems : 1
NumberOfPositions : 4
OperationMode : Manual
OutputType : Digital
PartNumber : PM Sensor SDS011
ProductDescription :
Communication protocol:
Serial communication protocol: 9600 8N1. (Rate of 9600, data bits 8, parity none, stop bits 1)
Serial report communication cycle: 1+0.5 seconds
Data frame (10 bytes): message header + order+ data(6 bytes) + checksum + message trailer
The number of bytes:Name:Content
0:message header:AA
order:C0
data 1:PM2.5 low byte
data 2:PM2.5 high byte
data 3:PM10 low byte
data 4:PM10 high byte
data 5:0(reserved)
data 6:0(reserved)
checksum:checksum
message trailer:AB
Checksum: data 1 + data 2 + ...+ data 6
PM2.5 data content: PM2.5 (ug/m3) = ((PM2.5 high byte*256 ) + PM2.5 low byte)/10
PM10 data content: PM10 (ug/m3) = ((PM10 high byte*256 ) + PM10 low byte)/10
Interface specification:
CTL:Control pin, reserved
1um:>0.3 Micron particle concentration, PWM Output
5V:5V power input
25um:>2.5 Micron particle concentration, PWM Output
GND:GND
R:Serial port receiver RX
T:Serial port transmission TXPS: The pitch of Interface is 2.54mm
Package included:
1 x PM Sensor SDS011 High Precision PM2.5 Air Quality Detection Sensor Module
ProductSiteLaunchDate : 2020-12-16T02:49:23.146Z
ResponseTime : 10 seconds
SensingDistance : 3 centimeters
Size : Small
SpecificUsesForProduct : Time
Style : Modern
SupplierDeclaredDgHzRegulation : not_applicable
TerminalType : Physical
UnitCount : 4
UpperTemperatureRating : 85 degrees_celsius
Voltage : 5 volts