Specification AgeRangeDescription : adult Brand : Mavaol BulletPoint : Brand: ELECTRO-FLYTE BulletPoint1 : [PROGRAMMABLE FUNCTION]: CUSTOMIZE SEQUENCE TRACE AS NEEDED BulletPoint2 : [BASIC VALUES]: OPERATING VOLTAGE DC12-24V, PC MATERIAL BulletPoint3 : [USE SCENARIO]: WIDELY APPLIED IN INDUSTRIAL AUTOMATION BulletPoint4 : [MADE OF PC MATERIAL]: STRONG AND CONSTRUCTION BulletPoint5 : [LIGHTWEIGHT]: EASY INSTALLATION FOR PRACTICAL INDUSTRIAL CONTROL Color : One Color ExternallyAssignedProductIdentifier : 7869106152074 IncludedComponents : DOES NOT APPLY ItemName : Programmable Controller Module Robust Offline Sequence Controller DC12‑24V Screen Structure 5 Digits PC Material Industrial Automation Control ItemPackageDimensions_Height : 4 centimeters ItemPackageDimensions_Length : 17 centimeters ItemPackageDimensions_Width : 11 centimeters ItemPackageQuantity : 1 ItemTypeKeyword : process-controllers Manufacturer : Mavaol ModelName : Mavaol2g9mvaxcso ModelNumber : Mavaol2g9mvaxcso NumberOfBoxes : 1 NumberOfItems : 1 PartNumber : Mavaol2g9mvaxcso ProductDescription : [PROGRAMMABLE FUNCTION]: CUSTOMIZE SEQUENCE TRACE AS NEEDED [BASIC VALUES]: OPERATING VOLTAGE DC12-24V, PC MATERIAL [USE SCENARIO]: WIDELY APPLIED IN INDUSTRIAL AUTOMATION [MADE OF PC MATERIAL]: STRONG AND CONSTRUCTION [LIGHTWEIGHT]: EASY INSTALLATION FOR PRACTICAL INDUSTRIAL CONTROL
Spec: Item Type: Programmable controller Material: PC Housing Size: Approx. 99.7 x 72 x 17mm / 3.93 x 2.83 x 0.67in (L x W x H) Screen Structure: 5 digit, high brightness digital tube Operating Environment: -5℃- 60℃ (no condensation) Working Voltage: DC12-24V, >1.5A, power supply Opening Size: Approx. 92 x 69.8mm / 3.62 x 2.75in (L x W) Output: 5 outputs the number of lines at the end of the loop, it is illegal. Will alarm F2Number of rows at the end of the loop Unit: rows (demonstrated below)0-4040 Illegal if the number of lines at the beginning of the loop > the number of lines at the end of the loop. Will alarm F3Open [Output] manual debugging interface (restart to exit automatically or press [Return])Introduced below0 F4Open [Input] manual debugging interface (restart to exit automatically or press [Return])Introduced below0 F5Turn on programming mode (restart to exit automatically)0-10 If you do not turn on the programming privileges, it is not possible to change the programming statements and alarm 0: Turn off programming privileges (power off automatically changes to 0) 1: Turn on programming privileges
F15Adjust the amplitude value of [overall working time] during Unit:second0-65535.999 , 0=no speed change during 0 F16Auto run at power on specified program line: 31-40 lines0-20 0 Turn off. If turned off, program segment 31-40 lines will automatically act as normal program category 1 Power on automatically runs program segment 31-40 lines. 2 The power on automatically works. F17Action when ESC emergency stop key is pressed0-20 0 Program ends and turns ProductSiteLaunchDate : 2024-11-28T11:48:44.335Z Size : One Size SupplierDeclaredDgHzRegulation : not_applicable SupplierDeclaredHasProductIdentifierExemption : 1 UnitCount : 1 UnspscCode : 40141600