Specification AgeRangeDescription : adult Brand : DWFSKZKV BulletPoint : Engine Interface Module EIM BASIC MK3 258-9753 Speed Controller Diesel Generator Engine Motor Charge Regulator 258-9755 Color : One Color ControllerType : Push Button Department : Unisex Adult ExternallyAssignedProductIdentifier : 7310389551066 HardwarePlatform : PC ItemName : DWFSKZKV ATS106 Automatic Transfer Switch Controller Module diesel generator control board panel genset part ItemPackageDimensions_Height : 1 centimeters ItemPackageDimensions_Length : 3 centimeters ItemPackageDimensions_Width : 2 centimeters ItemPackageQuantity : 1 ItemTypeKeyword : process-controllers Manufacturer : DWFSKZKV Material : Copper ModelName : DWFSKZKV ModelNumber : DWFSKZKV NumberOfBoxes : 1 NumberOfItems : 1 PartNumber : DWFSKZKV ProductDescription : ATS1 06 Automatic Transfer Switch Control Module
1. Summary ATS106 is an Automatic Transfer Switch Control Module.The module features 32 -Bit microprocessor control.Once mains AC supply failure are detected (under voltage, over voltage), The module will control generator to start . If generator AC can load, The module automatically transfer the switch to generator AC supply. 2. Features Micro-processor based design; Meter two single -phase AC Voltages ; Set AUTO or MANUAL via PUSH BOTTON mounted on the front panel; Two isolable N designed ; 7 LEDs display the status ; Operational timers can be altered by PC; Control generator to Start. 3. Specification DC supply: 8 to 35V(1.5VA) Single -phase AC input : AC30-277V (+20%) 50/60Hz Relay output: Relay of close mains & close gens 16A 250VAC Relay of start generator 5A 250VAC Delay timers Mains Normal delay time 03 600s Mains Abnormal delay time 03600s Gens Normal delay time 0~3600s Start generator time:0~3600s(after Mains is abnormal) Stop generator time: 0~3600s(after Mains is normal) Close time:0~20.0s Over close time: 0~5.0s Between close time: 0~3600s Critical value: Mains under voltage: 0~360V Mains over voltage:0~360V Gens under voltage:0~360V Gens over voltage:0~360V Gens under frequency : 0~60.0Hz Gens over frequency : 51.0~75.0Hz Accessorial input:state can be altered by PC Operating Temperature Range: -30 to +70 Terminal: 1(B -):connect to the cathode of battery. 2(B+):connect to the anode of battery. 3(Close Gens Input):Gens supply closed auxiliary input, connect to ( B -) is active. 4,5(Gens Start Output):output of Relay of start gens (volts free , 5A250V). 6,7(Gens AC Input):Gens AC Input. 8,9(Mains AC Input):Mains AC Input. 10,11(Close Mains Output):output of Relay of close mains (volts free ,5A250V). 12,13( Close G ProductSiteLaunchDate : 2024-05-24T12:53:22.297Z Size : One Size UnitCount : 1 UnspscCode : 39122200 Voltage : 24 volts