XYgdhqpt Swimming Pool Electrodes Compatible with Power Ionizer Chamber,replacement electrodes(0.5IN by 0.5IN by 2.5IN)

Imported from USA | Ships in 10 working days

5% instant discount on non COD

1

₹ 7000/-

The price at cart2india.com is inclusive of custom duties, GST, freight forwarding and other charges.

Free Shipping across India. Powered by BlueDart

Product Information


Specification
Brand : XYgdhqpt
BulletPoint1 : [PRODUCT DESCRIPTION]:The copper/silver electrodes erode inside the chamber. This is the only reason you have to replace the chamber.If you want to replace a replacement room, why not replace the electrodes inside? This is a good choice and less expensive.
BulletPoint2 : [PACKAGING INCLUDES]:Packaging includes TWO copper/silver electrodes that will replace the eroded electrodes in your current ionizer chamber. The measurement of the replacement electrodes are ½ by ½ by 2.5 inches. (2) Stainless Steel Screw (2) Spade Terminal(2) Lockwasher(2) Sealing Washer
BulletPoint3 : [SIMPLE INSTALLATION]:Only cross screwdriver and long Needle-nose pliers are required.1. Remove chamber from transformer module. 2. Loosen stainless steel screws and push up on them. This will unseat the eroded electrodes from the square socket that each electrode is setting in. 3. After the electrodes are loose finish removing screws and electrodes from chamber.
BulletPoint4 : 4. Using the long needle nose pliers insert one replacement electrode into the short side of the chamber where the old electrodes once sat. 5. While holding the electrode with the pliers start the screw from the bottom side of the chamber. You will be able to feel the new electrode start to reseat back into the socket where the old electrode once sat. 6. Tighten screw securely making sure that the spade terminal is pointing toward the long end of the chamber. 7. Repeat steps 4, 5 and 6 with the
BulletPoint5 : [NOTE]:Do not install washers or spade terminal in any other order. The sealing washer has to go next to the chamber to keep it from leaking. Please confirm that the parts are the correct ones you need before purchasing. If you are not sure, please contact us for verification.
Color : Pack of 6
ExternallyAssignedProductIdentifier : 5056386882292
ExternallyAssignedProductIdentifier1 : 0713072784067
ExternallyAssignedProductIdentifier2 : 713072784067
ExternallyAssignedProductIdentifier3 : 00610377492256
ItemDisplayDimensions_Height : 1 inches
ItemDisplayDimensions_Width : 1 inches
ItemDisplayWeight : 1 pounds
ItemName : XYgdhqpt Swimming Pool Electrodes Compatible with Power Ionizer Chamber,replacement electrodes(0.5IN by 0.5IN by 2.5IN)
ItemPackageDimensions_Height : 7.5946 centimeters
ItemPackageDimensions_Length : 3.2004 centimeters
ItemPackageDimensions_Width : 7.5946 centimeters
ItemPackageQuantity : 1
ItemShape : Square
ItemTypeKeyword : swimming-pool-and-spa-replacement-parts
ItemTypeName : swimming pool electrodes
Manufacturer : XYgdhqpt
Material : copper
ModelNumber : SPX0714Z1
NumberOfItems : 2
PartNumber : SPX0714Z1
ProductDescription : The copper/silver electrodes erode inside the chamber. This is the only reason you have to replace the chamber.If you want to replace a replacement room, why not replace the electrodes inside? This is a good choice and less expensive. Only cross screwdriver and long Needle-nose pliers are required. 1. Remove chamber from transformer module. 2. Loosen stainless steel screws and push up on them. This will unseat the eroded electrodes from the square socket that each electrode is setting in. 3. After the electrodes are loose finish removing screws and electrodes from chamber. 4. Using the long needle nose pliers insert one replacement electrode into the short side of the chamber where the old electrodes once sat. 5. While holding the electrode with the pliers start the screw from the bottom side of the chamber. You will be able to feel the new electrode start to reseat back into the socket where the old electrode once sat. 6. Tighten screw securely making sure that the spade terminal is pointing toward the long end of the chamber. 7. Repeat steps 4, 5 and 6 with the other electrode. 8. Reinstall the chamber back onto the transformer module.
ProductSiteLaunchDate : 2020-09-11T02:15:06.866Z
Size : 39010200 Tank Clamp O-Ring
SupplierDeclaredDgHzRegulation : not_applicable
UnitCount : 1
WaterResistanceLevel : waterproof

Questions & Answers

Have a question? Ask experts

?
No question found

Ratings & Review

Rating Breakdown (average)

5*
0
4*
0
3*
0
2*
0
1*
0

No reviews found.

Have an opinion on this page? Let's hear it.