Specification
Brand : Pentair
BulletPoint1 : The heater is equipped with two Stack Flue sensors one for each heat exchanger.
BulletPoint2 : These sensors monitor the stack flue temperature and if needed will shut down the heater if the stack flue temperature exceeds 170° F (77° C).
BulletPoint3 : Compatible Replacement for Minimax NT STD, NT LN, NT TSI Model 200, 250, 300, 400
BulletPoint4 : Also Compatible Replacement for MiniMax CH pool and spa heater models 150 IID, 150, 200, 250, 300, 350, 400
BulletPoint5 : NOTE: This is a compatible aftermarket replacement part. The manufacturers' names and part numbers have been used for reference purposes only. Optimum Pool Technologies Inc is an independent brand.
Color : almond
CustomerPackageType : Standard Packaging
ExternallyAssignedProductIdentifier1 : 788379878115
ExternallyAssignedProductIdentifier2 : 0788379878115
ExternallyAssignedProductIdentifier3 : 00788379696160
ItemDisplayDimensions_Height : 1.9 inches
ItemDisplayDimensions_Length : 6.4 inches
ItemDisplayDimensions_Width : 2.8 inches
ItemDisplayWeight : 1 pounds
ItemName : Pentair 475601, almond
ItemPackageDimensions_Height : 1.9 inches
ItemPackageDimensions_Length : 6.4 inches
ItemPackageDimensions_Width : 2.8 inches
ItemPackageQuantity : 1
ItemTypeKeyword : swimming-pool-heater-and-heat-pump-parts
ItemTypeName : 475601
Manufacturer : PENTAIR WATER POOL AND SPA, IN
Material : Rubber
ModelName : 475601
ModelNumber : 475601
NumberOfBoxes : 1
NumberOfItems : 1
PackageLevel : unit
PartNumber : 475601
PowerSourceType : manual
ProductDescription : This Compatible Repalcement for 471587 High Limit Switch is an important switch in your MiniMax NT pool heater, and is used to detect when your water temperature has exceeded a safe level (115°F). You MiniMax NT heater will indicate when it is time to replace the High Limit Switch when the “SERVICE” LED is displayed. It also may be time to replace your MiniMax NT High Limit Switch if all 3 lights on the back of the control board are on and one or both of the switches shows an open circuit (given proper water flow through the heater).
SupplierDeclaredDgHzRegulation : not_applicable
Voltage : 230 volts