Specification Amperage : 4 amps Brand : Pongnas BulletPoint1 : [Multiple Reset Methods] Tailored reset options for diverse requirements. BulletPoint2 : [Intelligent Functionality] Digital display for convenient motor status monitoring and fault record function for enhanced intelligence. BulletPoint3 : [Power,down ] The protector ensures motor startup after power loss. BulletPoint4 : [Comprehensive ] Overcurrent, phase failure, overload, and underload . BulletPoint5 : [Easy Installation] Rail mounted method for effortless setup. ExternallyAssignedProductIdentifier : 3606485332499 ItemName : Motor Integrated Protector, 3,Phase Digital Phase,Failure OverorUnder Load Protector AC380V 3,160A, easy installation and intelligent operation with fault record function ItemPackageDimensions_Height : 7 centimeters ItemPackageDimensions_Length : 11 centimeters ItemPackageDimensions_Width : 10 centimeters ItemPackageQuantity : 1 ItemTypeKeyword : phase-monitoring-relays Manufacturer : Pongnas Material : Plastic ModelName : Pongnas04krpgnh53 ModelNumber : Pongnas04krpgnh53 NumberOfItems : 1 PackageLevel : unit PartNumber : Pongnas04krpgnh53 PhaseType : Three Phase ProductDescription : [Multiple Reset Methods] Tailored reset options for diverse requirements. [Intelligent Functionality] Digital display for convenient motor status monitoring and fault record function for enhanced intelligence. [Power,down ] The protector ensures motor startup after power loss. [Comprehensive ] Overcurrent, phase failure, overload, and underload . [Easy Installation] Rail mounted method for effortless setup.
Spec:
Item Type Motor Protectorandnbsp; Item Operating conditions and setting range Action time Overload (definite time limit) The running current exceeds the set value 0.5,60s Setting range: 0.3,16A, 3,160A, 10,999A. Overload (inverse time limit) Operating current exceeds the set value 1,5 tripping curve inverse time limit Setting range: 0.3,16, 3,160A, 10,999A Underload The operating current is lower than the set value. Put in after startup. 0.5,60s The setting range is the same as the overload. Note: The underload value must be less than the overload value. Phase failure Current imbalance rate exceeds 50% 2s Current imbalance The current imbalance rate exceeds the set value. Setting range: 10,50% 5s Unbalance rate = phase current - I average current maximum / I average current x Start delay During the start,up of the motor, the protector will against overload, underload, locked,rotor, and unbalance . Note: A countdown will occur during the boot process. 0,200s Locked,rotor The running current exceeds the set overload factor and is put into operation after the startup. 3s Setting range: 1.5,8 times overload current. Short circuit The operating current exceeds 10 times the set overload factor. ≤50MS Leakage The zero sequence current exceeds the set value. Setting range: 30ma,2.5A. 1S A 5Aor10mA zero,sequence current transformer must be ProductSiteLaunchDate : 2024-10-15T06:28:06.443Z Size : 2.5-4A SupplierDeclaredDgHzRegulation : not_applicable UnspscCode : 27112800 Voltage : 690 volts Wattage : 1.5 kilowatts