PXS-Ca Desktop Digital Calcium Concentration Meter with Range 40g/L -400ug/L

Imported from USA | Ships in 10 working days

5% instant discount on non COD

1

₹ 108800/-

The price at cart2india.com is inclusive of custom duties, GST, freight forwarding and other charges.

Free Shipping across India. Powered by BlueDart

Product Information


Specification
Brand : HFCCYBGS
BulletPoint1 : 1、PXS-Ca calcium ion concentrator is produced by using microcontroller technology, which makes operation simple and convenient, and digital display intuitive and correct.
BulletPoint2 : 2、Instrument has manual temperature compensation and automatic temperature compensation functions (when the temperature electrode is connected, the instrument enters automatic temperature compensation and displays the current temperature; When the temperature electrode is not connected, the instrument enters the manual temperature compensation, and the instrument displays the manual temperature setting value.
BulletPoint3 : 3、Instrument has a calcium ion concentration value [Ca] display in addition to pF value display.
BulletPoint4 : 4、Instruments are beautiful and lightweight.
ExternallyAssignedProductIdentifier1 : 0774113059230
ExternallyAssignedProductIdentifier2 : 774113059230
IncludedComponents : HOST AND SENSOR
ItemName : PXS-Ca Desktop Digital Calcium Concentration Meter with Range 40g/L -400ug/L
ItemPackageDimensions_Height : 31.496 centimeters
ItemPackageDimensions_Length : 5.08 centimeters
ItemPackageDimensions_Width : 7.112 centimeters
ItemPackageQuantity : 1
ItemTypeKeyword : science-lab-ph-meters
Manufacturer : HFCC
MeasurementAccuracy : 0.02pCa
ModelNumber : PXS-Ca
NationalStockNumber : 6630-00-359-9889
NumberOfItems : 30
PartNumber : 240104
ProductDescription : ▲Main technical parameters
▲1.1 measurement range:
A) pCa value :(0.00 ~ 6.00) pCa;
B) Ca concentration: 40g/ L-400ug /L.
C) mV value :(-1800 ~ 1800) mV.
▲1.2 defense rate: 0.01 pCa
Basic error of electronic unit: + / - 0.02pCa + / - 1 word.
▲1.4 basic error of the instrument:
Calculation error of pF ~ [Ca] concentration conversion: + / - 0.3%(reading).
▲1.5 instrument repeatability error: no more than 0.03pCa + / - 1 word.3.7 temperature compensation range test solution (5.0 ~ 50.0) ℃
▲1.6 stability of electronic unit: + / + 0.02pCa /3h.
▲1.7 normal working conditions of the instrument:
A) the environment temperature (5 ~ 40 ℃;
B) relative humidity: no more than 80%;
C) power supply: AC 220V /110V; Frequency of 50/60 ±1 Hz
D) no other magnetic field interference other than the earth's magnetic field;
E) no significant vibration.
▲1.8 dimensions: 1 x b x h, mm: 210 x 190 x 80
Weight: 1.5kg

ProductSiteLaunchDate : 2024-01-03T08:00:00.000Z
StreetDate : 2017-03-14T00:00:01Z
SupplierDeclaredDgHzRegulation : not_applicable
UnitCount : 1
UnspscCode : 41113700

Questions & Answers

Have a question? Ask experts

?
No question found

Ratings & Review

Rating Breakdown (average)

5*
0
4*
0
3*
0
2*
0
1*
0

No reviews found.