Specification Alarm : Visual BatteriesIncluded : 1 BatteriesRequired : 1 Brand : Smgda BulletPoint1 : AC / DC Voltage: 10V / 50V / 250V / 1000V ; DC Current: 0.5mA / 50mA / 500mA BulletPoint2 : Manual range selection, Analog Multimeter with test lead pair and 1x AA battery full set. BulletPoint3 : Multiple protection. Adopt overvoltage, overcurrent self fusing protection circuit, meter overload protection, etc. BulletPoint4 : Suitable for machine maintenance, communication, power, circuit equipment maintenance, colleges and universities student experiment, etc. BulletPoint5 : Easy to read, color-coded analog displays BulletPoint6 : Case Only Capacity : 0.03 cubic_inches Color : Black CustomerPackageType : Standard Packaging ExternallyAssignedProductIdentifier1 : 783335103584 ExternallyAssignedProductIdentifier2 : 0783335103584 ExternallyAssignedProductIdentifier3 : 00649553344157 IncludedComponents : Test Pen & AA battery ItemName : Smgda Analog Multimeter, AC/DC Volt 1000V Voltmeter Amp Volt Ohm Voltage Tester Meter with Test Leads and Battery Included ItemPackageDimensions_Height : 17.2974 centimeters ItemPackageDimensions_Length : 3.4036 centimeters ItemPackageDimensions_Width : 9.8044 centimeters ItemPackageQuantity : 1 ItemTypeKeyword : multi-testers Manufacturer : Smgda Material : Metal, Plastic MeasurementAccuracy : +/-5V MeasurementType : Multimeter MeasurementType1 : Multimeter MeasurementType2 : Voltmeter MeasurementType3 : Voltmeter MinimumOperatingVoltage : 10 volts_of_direct_current ModelNumber : EPC_INS_11V NumberOfCompartments : 1 NumberOfItems : 1 PartNumber : INS_11V Pattern : Solid PowerSourceType : Battery Powered ProductDescription : Parameter Information: Style: Pointer-type Material: ABS DC Voltage: 10V / 50V / 250V / 1000V AC Voltage: 10V / 50V / 250V / 1000V DC Current: 0.5mA / 50mA / 500mA Operating Mode: Handheld Product Description: Product Name: Analog Pointer Multimeters Testing Instrument Features: - Pocket multimeter, with multiple measurement functions, full range protection and high safety performance. - The scale is accurate, the dial is clear, the gear is accurate, and the sense of pause between gears is strong. - The regulation is simple and convenient, the workmanship is exquisite, and the measurement is accurate. - Multiple protection. Adopt overvoltage, overcurrent self fusing protection circuit, meter overload protection, etc. - Made of engineering plastics, is light in whole, small in size and convenient to carry. - Suitable for machine maintenance, communication, power, circuit equipment maintenance, colleges and universities student experiment, etc. - Especially suitable for e-learning classes, amateur radio experiment of primary school students. Product Model: MF-110A Range Display: Mechanical pointer needle Operation mode: Manual range Protective design: Insulating material Power Supply: 1 x AA battery (Included) Points for attention - 1.Before measurement, check whether the position of the range selection knob is correct. - 2.If the current or voltage to be measured is unknown, set the measuring range to the highest gear, and conduct the measurement after correct measurement and selection. - 3.The maximum DC current range is 250(500)mA, and the maximum voltage range is 500(1000)V. Measurement Steps: - 1.First check whether the pointer is on the zero indexing line, otherwise turn the zero adjuster for adjustment. - 2.DC Current (DCA) - (1)Insert the red plug of the test rod into the instrument "+" and the black plug into the instrument "-". - (2)Set the measuring range to the highest gear of the current measuring range. - (3)Contact the probe of the test rod with the circuit to be tested and connect it in series with the circuit to be tested. - (4)Read the indicated value from the second scale (mAV) of the dial. - (5)If the reading on the scale is too small, turn down one gear until the best indication is obtained. - 3.DC / AC Voltage (DCV, ACV) - (1)Set the range selection to the maximum limit of voltage. - (2)Connect the probe of the test rod across the circuit under test (in parallel). - (3)Read the indicated value from the second scale. Note that the 10V gear reads the indicated value from the third scale (special for AC 10V). - (4)If the reading on the scale is too small, turn down one gear until the best indication is obtained. - 4.Resistance (OHM) - (1)Set the measuring range to the corresponding gear. - (2)Short circuit the probe of the test rod and adjust the adjustment knob to stop the pointer on the zero ohm dividing line. If the pointer cannot be adjusted to the zero ohm dividing line, the battery is exhausted and needs to be replaced. - (3)Read the resistance value from the first scale (OHM) during measurement. - (4)Use the test rod probe to measure the resistance of the device under test, which shall be connected in series with the device under test. - (5)Note: If the resistance of the circuit is measured, cut off the power supply of the circuit and discharge all capacitors. Place of Application: Battery / Resistance / DC Current Test Machine Maintenance / Communication / Power / Circuit Equipment Maintenance Note: If the resistance of the circuit is measured, cut off the power supply of the circuit and discharge all capacitors. The multimeter is a normal product, only for simple measurements. Product Weight : 88 G / 3.10 Ounces Product Dimensions (L*W*H) : 100*80*30 MM / 3.94*3.15*1.18 Inches Package Weight : 90.0 G / 3.17 Ounces Package Dimensions (L*W*H) : 100*80*30 MM / 3.94*3.15*1.18 Inches Retail Packaging: Yes, Plastic Packaging Package Include: 1 x MF-110A AC/DC Analog Multimeter (Included Battery) 2 x Test Pen ProductSiteLaunchDate : 2024-03-29T09:46:46.098Z Size : External CT StreetDate : 2017-09-30T00:00:01Z Style : analog SupplierDeclaredDgHzRegulation : not_applicable SupplierDeclaredHasProductIdentifierExemption : 1 TargetGender : unisex UnitCount : 1 UnspscCode : 41113600 UpperTemperatureRating : 40 degrees_celsius