SpecificationAmperage : 27 amps
Brand : Eaton
BulletPoint : DW4869
BulletPoint1 : 3 pole, NEMA Size 1, Coil voltage 120 Volts, 60 Hertz
BulletPoint2 : Motor voltage 200, 230, 460, 575 Volts, Non-reversing
BulletPoint3 : Max hp - 200/230 V - 1 hp, 460/575 V - 2 hp, Brownout protection
BulletPoint4 : Continuous Amperes (Enclosed) 27 Amps, Selectable trip class, 10, 20, 30 or no protection
BulletPoint5 : Motor protection - heaters not required, selectable settings
Color : White
CurrentRating : 200 amps
ExternallyAssignedProductIdentifier1 : 0786678630601
ExternallyAssignedProductIdentifier2 : 786678630601
Hazmat : 32000000
IncludedComponents : AC CONTACTOR
ItemDisplayDimensions_Depth : 3.2 inches
ItemDisplayDimensions_Diameter : 1.2 inches
ItemDisplayDimensions_Height : 1.2 inches
ItemDisplayDimensions_Length : 3.2 inches
ItemDisplayDimensions_Width : 1.2 inches
ItemName : Eaton Starter Open Sz1l 120v C-h Advantage Series
ItemPackageDimensions_Height : 21 centimeters
ItemPackageDimensions_Length : 18 centimeters
ItemPackageDimensions_Width : 16 centimeters
ItemPackageQuantity : 1
ItemTypeKeyword : electronic-motor-starters
Manufacturer : Eaton
Material : Copper
ModelNumber : LR9F5371
NumberOfItems : 1
OperatingVoltage : 24 volts
PackageLevel : unit
PartNumber : W200MLCFC
PhaseType : Full Phase
ProductDescription :
A versatile NEMA Size 1 non-reversing motor starter, part of the EATON Advantage Range, features 3 poles, brownout protection a 120 V coil rating and requires no heaters. Small in stature, this starter doesn?t consume all the real estate within your installation. Features include communication capability, a high contact force and minimised bounce times, selectable trip class, common auxiliary contacts and 2% accuracy overload protection. This versatile motor starter is suitable for a wide range of industrial applications.
This W200 motor starter includes a solid state current-sensing unit that provides overload protection, phase loss protection, phase imbalance protection, and ground current-sensing protection The starter trips when it detects that phase loss, phase imbalance, ground current or significant overload conditions exist. The starter needs to be reset after tripping before it can be turned on again. These settings can be turned off using the DIP switch settings.
A class W200 motor starter provides the same overload protection as a Class 10/20/30 overload relay without the need for heater elements and the heat loss of a thermal overload relay.
ProductSiteLaunchDate : 2009-08-01T04:00:00-00:00
Size : HWPY112040CC
SpecificationMet : UL
Style : 4NC
SupplierDeclaredDgHzRegulation : not_applicable
UnitCount : 1
UnspscCode : 39121521
Voltage : 120 volts
Wattage : 1.2 kilowatts