Specification Brand : YWBL-WH BulletPoint : PWM dc motor speed controller max 60A CW CCW digital display 0~100% drive module Input 10V~55V BulletPoint1 : ABS Shell: The shell is made of industrial grade ABS plastic, has high impact and heat , strong flame retardancy and good comprehensive performance. BulletPoint2 : Easy to Operate: Designed with user friendly keyboard, and equipped with digital display screen, easy and convenient to operate. it can be widely applied to drive the AC motor, such as fans, pumps, power tools, etc. BulletPoint3 : High Performance Motherboard: Select high end motherboard, intelligent and efficient, has strong performance and complete functions. BulletPoint4 : Full SMD Design: All internal components adopt SMD design, which greatly increases the stability of the machine performance. BulletPoint5 : Good Heat Dissipation: Built in super large heat sink with small fan, the heat sink is about 3 times larger than which of similar products, the fan has low noise when running, and assisting good heat dissipation. ExternallyAssignedProductIdentifier1 : 0708310788938 ExternallyAssignedProductIdentifier2 : 708310788938 ItemName : Motor Variable Frequency Drive VFD Digital Display Motor Frequency Converter, 3 Phase 380-440V Input Variable Frequency Inverter (3kw) ItemPackageDimensions_Height : 17.7 centimeters ItemPackageDimensions_Length : 13.8 centimeters ItemPackageDimensions_Width : 17.6 centimeters ItemTypeKeyword : motor-speed-controllers Manufacturer : YWBL-WH Material : plastic ModelName : YWBL-WHxi721ceawv-14 ModelNumber : YWBL-WHxi721ceawv-14 NumberOfItems : 1 PartNumber : YWBL-WHxi721ceawv-14 ProductDescription : Specifications: Item Type: Motor Variable Frequency Drive Material: ABS Storage Temperature: -25℃ to +55℃ Input Voltage: Three Phase 380-440V AC Output Voltage: Three Phase 0-440V AC
Packing list: 1 xMotor Variable Frequency Drive 1 x Manual
Notice: 1. Before wiring, please confirm whether the input power is in a power off state. 2. The wiring shall be carried out by professional electrical engineering personnel. 3. The grounding terminal must be grounded. 4. After the emergency stop circuit wiring is completed, be sure to check whether the action is valid. 5. Do not connect the output wire of the inverter with the shell, and do not short circuit the output wire. 6. Please confirm whether the voltage of the AC main circuit power supply is consistent with the rated voltage of the inverter. 7. Do not perform withstand voltage test on the inverter. 8. Please connect the braking resistor according to the wiring diagram. 9. Do not connect the power wire to the output U, V, W terminals. 10. Do not connect the contactor to the output circuit. 11. Be sure to install the protective cover before powering on. When removing the cover, be sure to disconnect the power. 12. The inverter that selects the reset and retry function should not be close to the mechanical equipment. Because it will restart suddenly when the alarm stops. 13. After confirming that the running is cut off, the alarm can be reset. If the alarm is reset in the state of running , the inverter may start suddenly. 14. Do not touch the terminals of the inverter. There is high voltage on the terminals, which is very dangerous. 15. While the power is on, do not change the wiring and do not remove or install the terminals. 16. Inspection and maintenance can only be carried out after the main circuit power supply is cut off. 17. Do not modify the inverter without ProductSiteLaunchDate : 2023-07-25T13:55:41.406Z Size : 3kw SupplierDeclaredDgHzRegulation : not_applicable UnitCount : 1 UnspscCode : 31160000