Specification Brand : RTELLIGENT BulletPoint1 : Modbus stepper driver: 24 - 100VDC or 18 - 80VAC power supply, 7.0A output current peak. Run the Modbus protocol over the RS485 network for real-time control of the drivers and motors. BulletPoint2 : It is a high-performance bus-controlled stepper motor driver with intelligent motion controller function and built-in S-shaped and deceleration instructions to set acceleration and deceleration independently. BulletPoint3 : Low Noise: Based on advanced control algorithm, the motor driver can run with low noise and low vibration BulletPoint4 : Application: This NT86 stepper motor driver can control almost all of 2 phase nema 34 stepper motors 86mm flange whose current is under 7.0A. Usually for production line, Li-on battery equipment, solar energy equipment, 3C electrical equipment, etc. BulletPoint5 : Warranty: Our step driver CNC controller has 12 months warranty. CE, ISO Certificated Color : Silver CurrentRating : 1.3 amps ExternallyAssignedProductIdentifier1 : 0791590889242 ExternallyAssignedProductIdentifier2 : 791590889242 Horsepower : 0.167 horsepower ItemName : RTELLIGENT Stepper Driver RS485 Modbus RTU Protocol 2 Phase for Nema 23/24/34 Open Loop/Closed Loop Step Motor (NT86) ItemPackageDimensions_Height : 27.686 centimeters ItemPackageDimensions_Length : 37.592 centimeters ItemPackageDimensions_Width : 27.432 centimeters ItemPackageQuantity : 1 ItemTypeKeyword : electronic-component-motor-drives Manufacturer : RTELLIGENT Material : Copper MinimumFrequency : 50 hertz ModelName : gear ModelNumber : VFD015EL43A NumberOfItems : 1 PartNumber : VFD015EL43A ProductDescription : Rtelligent NT60 is a MODBUS / RTU stepper motor with RS485 communication suitable for 4-wire 2-phase Nema 23/24 stepper motors with a flange of 57/60 mm and currents less than 5.0A.
Functions: ▶ Slave address setting: SW1-SW5,the five DIP switches, are used to set 32-bit DSP addresses in total. Please select the corresponding position according to the drive panel. ▶Baud rate setting: SW6-SW7, the two DIP switches, are used to select a total of 4 baud rates in total. The master and slave must be set to the same baud rate. Please selectthe corresponding position according to the drive panel. ▶Terminal matching resistor: sw8 is used to select whether the 120 ohm terminating resistor is valid, off is invalid, and on is valid. ▶Cn interface: 4 single input port, 2 output port. ▶Encoder interface: GND : Internal power supply output GND; +5 V : Internal power supply output 5V. When operating in the closed-loop mode, 5V power is supplied to the encoder. The maximum output current of this 5v signal should not exceed 150mA.IN2-, IN2+ : The differential input signal, the 5v level signal, can receive the pulse signal when the external pulse is open loop, and the quadrature encoder A phase signal in the closed loop mode. IN1-, IN1+ : Receives the quadrature encoder B-phase signal as the IN2 port. ▶ RJ45 interface: Network communication interface, also used to connect PC debugging software. ▶ Power and Motor interface V-, V+ is powered by DC power supply. 24 - 50V DC is recommended for the operating voltage range, the power supply is greater than 150W. A+, A-, B-, and B+ are respectively connected to the A and B phase windings of the two-phase motor.
Specifications: ▶ Debugging software interface: USB to 485 ▶ Maximum current : 5A ▶ Dimension: 118*75.5*33mm ▶ Power supply : 24~50V DC; 36V or48V recommended.