Specification Brand : Greatshow BulletPoint1 : Parts Connect Sequencer part number PCQ105. BulletPoint2 : 24 Volts DPST-SPST 2 Timing / 3 Switch Off 1-110 Seconds On 1-110 Seconds PSQ Models are Direct Replacement for Most Fan / Heat Sequencing Functions. BulletPoint3 : Replacement for Numbers: Diversitech DGS105, Klixon 51172-32, Mars 33232, 33832, Napco NS105, Supco Q105, White Rodgers 24A34-5, Watsco TDR30, York 525-37327-000. BulletPoint4 : Pick stores inside case along with five CH20 gaskets (5 included) for protection and safety. BulletPoint5 : 19047 Gasket Removal Tool for Manifold Charging Hoses CircuitType : 3-way Color : Black ConnectorType : Screw Terminals ControllerType : Heating Sequencer Controller ControlMethod : touch ExternallyAssignedProductIdentifier : 7073509326967 ExternallyAssignedProductIdentifier1 : 0641440694246 ExternallyAssignedProductIdentifier2 : 641440694246 Horsepower : 1.5 horsepower InternationalProtectionRating : IP41 ItemDisplayWeight : 133 ounces ItemName : Electric Heat Sequencer Control DPST-SPST 24 Volt for Q105 24A34-5 525-37327-000 ItemPackageDimensions_Height : 2.5 inches ItemPackageDimensions_Length : 3.9 inches ItemPackageDimensions_Width : 3 inches ItemPackageQuantity : 1 ItemTypeKeyword : hvac-controls Manufacturer : Greatshow Material : Copper ModelNumber : PCQ105 MountingType : Panel Mount NumberOfItems : 1 NumberOfPositions : 5 OperationMode : automatic PartNumber : ClimaTek Rplm for PYN # 320725-753 ProductDescription : Electric Heat Sequencer Control DPST-SPST 24 Volt for Q105 24A34-5 525-37327-000 Parts Connect Sequencer part number PCQ105. 24 Volts DPST-SPST 2 Timing / 3 Switch Off 1-110 Seconds On 1-110 Seconds PSQ Models are Direct Replacement for Most Fan / Heat Sequencing Functions. Replacement for Numbers: Diversitech DGS105, Klixon 51172-32, Mars 33232, 33832, Napco NS105, Supco Q105, White Rodgers 24A34-5, Watsco TDR30, York 525-37327-000. COMBINED LOAD RATING TABLE (ALL MODELS) 30A @ 240 VAC TOTAL, 23A Non-Inductive + 7 FLA / 42 LRA Inductive, ON Time: Elapsed time to make contacts after heater is energized (min. to max.) OFF Time: Elapsed time to break contacts after heater is de-energized (min. to max.) M1-M2 and M3-M4 are always first switches to turn ON and last to turn OFF. All other switches are random ON and random OFF NOTE : Underwriters Laboratories requires a fan interlock circuit to insure the blower remains operating whenever more than one sequencer is used. The fan interlock should be the M1/ M2 contacts of the second or third sequencer. All M1/ M2 contacts are wired to the blower motor so that any sequencer that is energized will keep the blower ON. part number PCQ105 Electric Heat Sequencer / Motor Fan Blower Control DPST-SPST 24 Volt for Q105 ProductSiteLaunchDate : 2019-10-31T14:25:07.690Z SupplierDeclaredDgHzRegulation : not_applicable SwitchType : Push Button TerminalType : Screw UnitCount : 1 UnspscCode : 39122200 Wattage : 7200 watts