Specification Brand : BURUREPAIRSHOP BulletPoint1 : Electric Heat Sequencer Control DPST 24 Volt for Q103 24A34-3 1056789 1256504 BulletPoint2 : Parts Connect Sequencer part number PCQ103. 24 Volts DPST 1 Timing / 2 Switch Off 40-110 Seconds On 1-20 Seconds Models are Direct Replacement for Most Fan / Heat Sequencing Functions. BulletPoint3 : Terminal Markings are Equivalent to Competitive Types. BulletPoint4 : Replacement for Numbers: Carrier HN67QC005, ICP (Heil, Comfortmaker, Tempstar, Arcoair) 1056789, HQ1056789, Diversitech DGS103, Goodman / Amana / Janitrol 1256504 BT1256504, Klixon E017, Mars 33244, 33844, Napco NS103, Supco Q103, White Rodgers 24A34-3. Watsco TDR20, York 525-37322-000. BulletPoint5 : COMBINED LOAD RATING TABLE (ALL MODELS) 30A @ 240 VAC TOTAL, 23A Non-Inductive + 7 FLA / 42 LRA Inductive, ON Time: Elapsed time to make contacts after heater is energized (min. to max.) OFF Time: Elapsed time to break contacts after heater is de-energized (min. to max.) M1-M2 and M3-M4 are always first switches to turn ON and last to turn OFF. BulletPoint6 : All other switches are random ON and random OFF NOTE : Underwriters Laboratories requires a fan interlock circuit to insure the blower remains operating whenever more than one sequencer is used. The fan interlock should be the M1/ M2 contacts of the second or third sequencer. All M1/ M2 contacts are wired to the blower motor so that any sequencer that is energized will keep the blower ON. Color : black ExternallyAssignedProductIdentifier1 : 0736994607887 ExternallyAssignedProductIdentifier2 : 736994607887 IncludedComponents : Electric Heat Sequencer ItemName : Electric Heat Sequencer Control DPST 24 Volt for Q103 24A34-3 1056789 1256504 ItemPackageDimensions_Height : 2 inches ItemPackageDimensions_Length : 3.1 inches ItemPackageDimensions_Width : 2.7 inches ItemTypeKeyword : hvac-controls Manufacturer : BURUREPAIRSHOP ModelName : 24A34-3 Electric Heat Sequencer ModelNumber : Q103 24A34-3 1056789 1256504 NumberOfItems : 1 ProductDescription : Electric Heat Sequencer Control DPST 24 Volt for Q103 24A34-3 1056789 1256504 Parts Connect Sequencer part number PCQ103. 24 Volts DPST 1 Timing / 2 Switch Off 40-110 Seconds On 1-20 Seconds Models are Direct Replacement for Most Fan / Heat Sequencing Functions. Terminal Markings are Equivalent to Competitive Types. Replacement for Numbers: Carrier HN67QC005, ICP (Heil, Comfortmaker, Tempstar, Arcoair) 1056789, HQ1056789, Diversitech DGS103, Goodman / Amana / Janitrol 1256504 BT1256504, Klixon E017, Mars 33244, 33844, Napco NS103, Supco Q103, White Rodgers 24A34-3. Watsco TDR20, York 525-37322-000. COMBINED LOAD RATING TABLE (ALL MODELS) 30A @ 240 VAC TOTAL, 23A Non-Inductive + 7 FLA / 42 LRA Inductive, ON Time: Elapsed time to make contacts after heater is energized (min. to max.) OFF Time: Elapsed time to break contacts after heater is de-energized (min. to max.) M1-M2 and M3-M4 are always first switches to turn ON and last to turn OFF. All other switches are random ON and random OFF NOTE : Underwriters Laboratories requires a fan interlock circuit to insure the blower remains operating whenever more than one sequencer is used. The fan interlock should be the M1/ M2 contacts of the second or third sequencer. All M1/ M2 contacts are wired to the blower motor so that any sequencer that is energized will keep the blower ON. ProductSiteLaunchDate : 2024-06-21T10:11:59.238Z SupplierDeclaredDgHzRegulation : not_applicable UnspscCode : 39120000