Specification Brand : Gearwell BulletPoint1 : The drainage pump is mainly used to remove contaminated condensate, and is used in air conditioning systems and refrigeration equipment. BulletPoint2 : The air conditioner drainage pump has a rate of 24m³/h and a maximum lift of 12 meters, can run with low noise and is safe and stable. BulletPoint3 : Circuit board sealing treatment, not affected by humid environment, better heat dissipation effect. BulletPoint4 : Electrode type water level sensor solves the failure problems of traditional float water level sensor such as water absorption and jamming. BulletPoint5 : The drainage pump has complete accessories, easy to assemble, and wall‑mounted installation can save space. Color : without pipe ExternallyAssignedProductIdentifier1 : 0761164462362 ExternallyAssignedProductIdentifier2 : 761164462362 IncludedComponents : 1 ItemName : Air Conditioning Pump, Silent Condensate Lift Removal System Assembly, 110‑240V 50‑60HZ, for HVAC Systems, Drainage Pumps, Home Appliances ItemPackageDimensions_Height : 9 centimeters ItemPackageDimensions_Length : 17 centimeters ItemPackageDimensions_Width : 11 centimeters ItemPackageQuantity : 1 ItemTypeKeyword : industrial-hvac-condensate-pumps Manufacturer : Gearwell Material : Acrylonitrile Butadiene Styrene ModelName : Gearwellvep6bisgcq ModelNumber : Gearwellvep6bisgcq NumberOfItems : 1 PartNumber : Gearwellvep6bisgcq ProductDescription :
Item Type: Air Conditioning Pump Model: M1 Material: Engineering Plastic Purpose: Air conditioning pump Voltage: 110-240V 50-60HZ Maximum Recommended : Approx. 12meters / 39.4ft Rate: 24m³/h Pumping Capacity: 24L/h Working Steam Consumption: 24L/H Suction Pressure: 2kpa Working Steam Pressure: 2mpa Applicable Maximum Cooling Capacity: 30000btu/h (within 3 horses) Water Storage Tank Capacity: 200ml Noise at 1 Meter: 19dB(A) Drive Mode: Electric Performance: Automatic Delivery Medium: Clean water pump Installation Method: Wall-mounted Operating Temperature: 0-50℃
Package List: 1 x Drain Pump 1 x Connection Line 2 x Screws 2 x Expansion Screws 1 x Buckle 1 x Cable Tie 1 x User Manual
Note: Please note that the new type and old type of this product will be sent randomly, and make sure you will not mind before ordering. The water in the air conditioner water tray must reach the water level, and the drainage pump can start normally.
ProductSiteLaunchDate : 2025-01-06T04:49:02.105Z Size : as described SupplierDeclaredDgHzRegulation : not_applicable UnitCount : 1 UnspscCode : 40151500 Voltage : 1