Specification Brand : ILOPM BulletPoint1 : 1. Pointer dial; dial design, the appearance is atmospheric, the dis-play is clear, and the reading is convenient. BulletPoint2 : 2. Fastening nut: Fastening knob design, can better lock the dial. BulletPoint3 : 3. Alloy probe; round cemented carbide probe design. BulletPoint4 : 4. The base is made of stainless steel, which is bright in color and not easy to rust. BulletPoint5 : l Add New user material function, to meet the need of user can test the special material. BulletPoint6 : materials, rubber, synthetic materials, oxide BulletPoint7 : film, phosphate film, etc. Color : One Color ExternallyAssignedProductIdentifier : 7509081999676 IncludedComponents : MAIN HOST ItemName : Durometer Tester, Butyl Rubber Shore Hardness Tester LX-A Type,Accurate Measurement ItemPackageDimensions_Height : 1 centimeters ItemPackageDimensions_Length : 3 centimeters ItemPackageDimensions_Width : 2 centimeters ItemPackageQuantity : 1 ItemTypeKeyword : hardness-testing-apparatus Manufacturer : ILOPM Material : metal MeasurementAccuracy : HIGH ACCURACY ModelName : dgdjngfmngf ModelNumber : dgdjngfmngf NumberOfBoxes : 1 NumberOfItems : 1 PartNumber : dgdjngfmngf ProductDescription : I. Overview LX-A rubber hardness tester is an instrument for measuring the hardness of vulcanized rubber and plastic products. This hardness tester is installed on a supporting load measuring rack of the same model, which can measure the standard hardness of rubber and plastic standard test pieces in the laboratory. You can also hold the head of the hardness tester to measure the apparent hardness of rubber (plastic) objects mounted on the equipment. 2. Main specifications and technical parameters 1. The range of pressing needle stroke: 0-25mm 2. Dial value: 0-100 3. Pressure at the end of the pressing needle: 0.55N—8.06N (56—822g) 3. How to use 1. Portable hardness tester Hold the hardness tester and press it flat on the sample (or test piece) until the bottom surface of the hardness tester is in full contact with the sample. At this time, the scale pointed by the pointer is the hardness value of the test piece (test piece), which is a stable measurement condition. The measurement accuracy should be measured on a fixed-load measuring rack of the same type as the supporting production. Three points should be selected in different positions for each measurement, and the arithmetic mean value should be selected. 2. Desktop hardness tester Press down the right handle to raise the workbench until it is in full contact with the glass platen. At this time, the pointer of the hardness tester should be 100 degrees. Put the sample on, and in the same way, you can get the change of the sample. Four, instructions for use, 1. Before the measurement, check that the pointer of the hardness tester should point to the zero position in the free state. For example (when the pointer deviates from the zero position, you can loosen the upper right corner compression screw, turn the surface, and align the zero position) when pressing the hardness tester on the glass plate (the end surface of the pressure needle and the bottom surface of ProductSiteLaunchDate : 2024-10-23T03:15:25.909Z Size : One Size SupplierDeclaredDgHzRegulation : not_applicable SupplierDeclaredHasProductIdentifierExemption : 1 UnitCount : 1 UnspscCode : 27110000