JFUDJKLI TVPS1-63B Dual Display 40A 63A 230V DIN Rail Adjustable Digital Over and Under Voltage Relay Surge Protector Limit Overcurrent Protection(40A)

Imported from USA | Ships in 10 working days

5% instant discount on non COD

1

₹ 12100/-

The price at cart2india.com is inclusive of custom duties, GST, freight forwarding and other charges.

Free Shipping across India. Powered by BlueDart

Product Information


Specification
AgeRangeDescription : adult
Brand : JFUDJKLI
BulletPoint : Ground Fault Circuit Interrupters
Color : One Color
ExternallyAssignedProductIdentifier : 9010062105156
ItemName : JFUDJKLI TVPS1-63B Dual Display 40A 63A 230V DIN Rail Adjustable Digital Over and Under Voltage Relay Surge Protector Limit Overcurrent Protection(40A)
ItemPackageDimensions_Height : 1 centimeters
ItemPackageDimensions_Length : 3 centimeters
ItemPackageDimensions_Width : 2 centimeters
ItemPackageQuantity : 1
ItemTypeKeyword : ground-fault-circuit-interrupters
Manufacturer : JFUDJKLI
ModelName : JFUDJKLI
ModelNumber : JFUDJKLI
NumberOfBoxes : 1
NumberOfItems : 1
PartNumber : JFUDJKLI
ProductDescription : Ground Fault Circuit Interrupters
scope
Function:
1. Overvoltage protection
2.Under voltage protection
3. Overcurrent protection
4.Automatic recovery
5. Voltage display (voltage measurement)
6. Current display (current measurement)
Product parameters:
1.Model: TVPS1-63B
2.Power supply: 230VAC 50/60Hz
3. Maximum load power: 1~40A adjustable (default: 40A)
1~63A adjustable (default 63A)
4. Overvoltage protection value range: 230V~300~OFF (default: 270V)
Overvoltage recovery voltage range: 225V--295V (default: 250V)
Overvoltage protection action time: 0.1s~30s (default: 0.5s)
Overvoltage recovery delay time: 1s~500s (default: 30s)
5. Undervoltage protection value range: 140V--210V --OFF (default: 170V)
Undervoltage recovery voltage range: 145V--215V (default: 190V)
Undervoltage protection action time: 0.1s~30s (default: 0.5s)
Undervoltage recovery delay time: 1s~500s (default: 30s)
6. Overcurrent adjustment range: 1-40A (default: 20A) 1-63A (default: 40A)
Overcurrent action range: 0.1~30 seconds (default: 0.5 seconds)
Overcurrent recovery delay time: 1s~500s (default: 30s)
7. Power-on delay time: 1s~500s (default: 10s)
<;2W
10. Motor life: 100,000 times
11. Installation method: 35mm DIN rail
Note: When connecting the product for the first time, you need to wait for about 10 seconds (power-on delay time: 1s~500s (default: 10s)). After the red light goes out, the product can work.
ProductSiteLaunchDate : 2024-10-07T07:12:25.878Z
Size : 40A
UnitCount : 1
UnspscCode : 39121601

Questions & Answers

Have a question? Ask experts

?
No question found

Ratings & Review

Rating Breakdown (average)

5*
0
4*
0
3*
0
2*
0
1*
0

No reviews found.

Have an opinion on this page? Let's hear it.