JFUDJKLI TVPS1-63 Dual Display 40A 63A 230V 63A 110V DIN Rail Adjustable Digital Over and Under Voltage Relay Surge Protector Limit Overcurrent Protection(110V 63A)

Imported from USA | Ships in 10 working days

5% instant discount on non COD

1

₹ 14000/-

The price at cart2india.com is inclusive of custom duties, GST, freight forwarding and other charges.

Free Shipping across India. Powered by BlueDart

Product Information


Specification
Brand : JFUDJKLI
BulletPoint : Ground Fault Circuit Interrupters
Color : One Color
ExternallyAssignedProductIdentifier : 9010062256827
ItemName : JFUDJKLI TVPS1-63 Dual Display 40A 63A 230V 63A 110V DIN Rail Adjustable Digital Over and Under Voltage Relay Surge Protector Limit Overcurrent Protection(110V 63A)
ItemPackageDimensions_Height : 1 centimeters
ItemPackageDimensions_Length : 3 centimeters
ItemPackageDimensions_Width : 2 centimeters
ItemPackageQuantity : 1
ItemTypeKeyword : ground-fault-circuit-interrupters
Manufacturer : JFUDJKLI
ModelName : JFUDJKLI
ModelNumber : JFUDJKLI
NumberOfItems : 1
PartNumber : JFUDJKLI
ProductDescription : Ground Fault Circuit Interrupters
scope
1. Overvoltage protection
2.Under voltage protection
3. Overcurrent protection
4.Automatic recovery
5. Voltage display (voltage measurement)
6. Current display (current measurement)
7. Voltage calibration: Voltage +-10% adjustable. A13
8. Current calibration: Current ±9/5% adjustable A15
9. Restore factory settings: Press and hold the down key for more than 12 seconds
10. Fault query: press the UP key for more than 12 seconds
Product parameters:
1.Model: TVPS1-63
2.Power supply: 230VAC 50/60Hz
3. Maximum load power: 1~40A adjustable (default: 20A)
1~63A adjustable (default 40A)
1~80A adjustable (default 60A)
4. Overvoltage protection value range: 230V~300~OFF (default: 270V)
Overvoltage recovery voltage range: 225V--295V (default: 250V)
Overvoltage protection action time: 0.1s~30s (default: 1s)
Overvoltage recovery delay time: 1s~500s (default: 30s)
5. Undervoltage protection value range: 140V--210V --OFF (default: 170V)
Undervoltage recovery voltage range: 145V--215V (default: 190V)
Undervoltage protection action time: 0.1s~30s (default: 1s)
Undervoltage recovery delay time: 1s~500s (default: 30s)
6. Overcurrent adjustment range: 1-40A (default: 20A) 1-63A (default: 40A) 1-80A (default: 60A)
Overcurrent action range: 0.1~30 seconds (default: 1s)
Overcurrent recovery delay time: 1s~500s (default: 30s)
7. Power-on delay time: 1s~500s (default: 10s)
<;2W
9. Motor life: 100,000 times
10. Installation method: 35mm DIN rail
110V version
1.Model: TVPS1-63C
2.Power supply: 110VAC 50/60Hz
3. Maximum load power: 1~63A adjustable (default: 40A)
4. Overvoltage protection value range: 80V~300~OFF (default: 145V)
Overvoltage recovery voltage range: 75V--295V (default: 140V)
Overvoltage protection action time: 0.1s~30s (default: 1s)
Overvoltage recovery delay time: 1s~500s (defaul
ProductSiteLaunchDate : 2024-10-08T08:33:26.987Z
Size : 110V 63A
UnitCount : 1