Specification Amperage : 20 amps Brand : Leviton BulletPoint1 : Sensor provides automatic on/off based on ambient lighting. Energy-efficient guide light uses approx. 1W of electricity - no bulbs to replace BulletPoint2 : Saves space by eliminating the need to use an outlet for a plug-in night light BulletPoint3 : For an added layer of protection, the GFCI regularly conducts an automatic internal test to confirm that it can respond to a ground fault BulletPoint4 : Patented lockout action prevents reset if GFCI is damaged and cannot respond to a ground fault BulletPoint5 : Slim, shallow design - reduced depth makes it easier to install BulletPoint6 : This GFCI socket with WR function is suitable for kitchens and bathrooms, as well as heating, air conditioning and refrigeration equipment within 25 feet. Ground fault circuit interrupter GFCI sockets are required to prevent electric shock in wet areas. Color : White CompatibleDevices : All ConnectivityProtocol : X-10 ConnectorType : Plug-In CurrentRating : 20 amps CustomerPackageType : Standard Packaging ExternallyAssignedProductIdentifier : 40078477714858 IncludedComponents : 3 Devices InternationalProtectionRating : UL ItemName : Leviton GFNL2-W Self-Test Smartlockpro Slim GFCI Tamper-Resistant Receptacle with Guidelight & LED Indicator, 20 Amp, 3 Pack, White ItemPackageDimensions_Height : 17.78 centimeters ItemPackageDimensions_Length : 10.414 centimeters ItemPackageDimensions_Width : 16.764 centimeters ItemPackageQuantity : 1 ItemShape : Rectangular ItemTypeKeyword : ground-fault-circuit-interrupter-outlets Manufacturer : Leviton Material : viton ModelNumber : GFNL2-W MountingType : Face NumberOfItems : 3 NumberOfPositions : 2 OperatingVoltage : 120 volts OperationMode : Off PartNumber : GFNL2-W ProductDescription : GFCI is a high-sensitivity, fast-response leakage protection device, which can quickly cut off the circuit and isolate the fault point when a dangerous ground fault leakage occurs, so as to avoid the occurrence of electrical accidents and ensure personal safety. The working principle of GFCI is that when there is equipment leakage or human body gets an electric shock, part of the current flows into the ground, and when the current flowing through the live wire and the neutral wire is not equal (the normal situation is equal), the GFCI monitors the current difference between the live wire and the neutral wire. Once the difference is greater than 6mA, the power supply can be cut off at the moment of 0.025 seconds, so as to ensure the safety of people and property. Widely used in homes, offices, hospitals, schools, hotels, factories and other outdoor venues. Specification:
Grounding: Standard Grounding
Rated Voltage: 125V
Rated Current: 15A/20A
Application: Residential/General-Purpose
Electrical Characteristics: AC125V/15A/20A
Color:White
Unloaded plug≥5000Sec Loop detection with automatic monitoring function
Meet the standard:UL,CUL
Housing material flame retardant grades
Tripping threshold:5mA Tripping time<25ms
Surge current:6000V/3000A 6000V/10KA
Electric strength:Pressure resistance1500V 50Hz Duration 1Min