DC Isolator Current Voltage Transmitter DIN Rail Mount 1 in 2 out 0?10V to 4?20mA GLG, Strong Versatility, Isolated Power Distribution

Imported from USA | Ships in 10 working days

5% instant discount on non COD

1

₹ 7100/-

The price at cart2india.com is inclusive of custom duties, GST, freight forwarding and other charges.

Free Shipping across India. Powered by BlueDart

Product Information


Specification
Brand : Garosa
BulletPoint1 : [Isolated Power Distribution] Distributes power while transmitting accurately
BulletPoint2 : [Versatile Installation] Fits 35mm standard rail for ease of use
BulletPoint3 : [Environmental ] Three-proof paint spraying circuit boards from erosion
BulletPoint4 : [Strong Anti-interference] Provides input/output/power supply isolation for reliability
BulletPoint5 : [Efficient Technology] Magnetic isolation ensures and low temperature drift
ItemName : DC Isolator Current Voltage Transmitter DIN Rail Mount 1 in 2 out 0‑10V to 4‑20mA GLG, Strong Versatility, Isolated Power Distribution
ItemPackageDimensions_Height : 3 centimeters
ItemPackageDimensions_Length : 13 centimeters
ItemPackageDimensions_Width : 12 centimeters
ItemTypeKeyword : function-generators
Manufacturer : Garosa
ModelName : Garosafrp1egchwa
ModelNumber : Garosafrp1egchwa
PartNumber : Garosafrp1egchwa
ProductDescription : Spec:

Item Type: DC Isolator
Material: ABS
Model: GLG
Channel: 1 in 2 out
PWR (15-, 16+): 24V DC
Input: 0-10V
Distribution Voltage: DC24V
2-Wire System: (9-, 13+)
3-Wire System: (9+, 10-, 13+)
Power Supply: (9+,10-)
Output:
Channel 1 (1+, 2-): 4-20mA
Channel 2 (3+,4-): 4-20mA
Output Current: Load≤500Ω
Output Voltage: Load≥10KΩ
Accuracy: 0.1% FS
Working Temperature Range: -20~+55℃
Electromagnetic Compatibility: with GB/T 18268 (1EC61326-1)
Applicable Field Equipment: Two-wire, three-wire transmitter, current source



Package List:
1 x DC Isolator

How To Use:
1. 35mm rail type installation, please pay attention to the stability and firmness of the card position during installation.
2. Please install it as vertically as possible to facilitate the heat dissipation inside the instrument.


Note:
1. The installation location must not have strong vibration, and the of electromagnetic interference from the terminal, power terminal and space exceeding the third type of industrial field electromagnetic interference in the IEC61000‑4 series.
2. There must be no harmful substances that cause severe to metal and plastic parts in the use environment.


ProductSiteLaunchDate : 2025-02-11T00:00:00.000Z
UnspscCode : 53120000

Questions & Answers

Have a question? Ask experts

?
No question found

Ratings & Review

Rating Breakdown (average)

5*
0
4*
0
3*
0
2*
0
1*
0

No reviews found.

Have an opinion on this page? Let's hear it.