Specification Brand : Wisoqu BulletPoint1 : All parts of the converter module are well-selected of good durability and . BulletPoint2 : The module can be used for interface conversion between PLC and frequency converter or matching control of interface between motion control card and frequency converter. BulletPoint3 : The module is stable and has great performance while using. BulletPoint4 : Input pulse level of 5/12/24V can be directly input without resistance.But input frequency should maintain more than 0.5 seconds. BulletPoint5 : The 0-1KHz frequency pulse is converted into a 0-10V analog voltage by this module. Color : #124 IncludedComponents : No ItemName : Voltage Converter Module,FV-1KHz10V Frequency Voltage Converter Module 0~1Khz to 0~10V Digital to Analog Module ItemPackageDimensions_Height : 3 centimeters ItemPackageDimensions_Length : 12 centimeters ItemPackageDimensions_Width : 9 centimeters ItemPackageQuantity : 1 ItemTypeKeyword : frequency-transducers Manufacturer : Wisoqu Material : copper ModelName : Kuuleyn54rfocpdai ModelNumber : Wisoqu5zagcm1dbs NumberOfBoxes : 1 NumberOfItems : 1 PartNumber : Wisoqu5zagcm1dbs PowerSourceType : Corded Electric ProductDescription : Specification: Item Type:Frequency to Voltage Converter Module Size:4.5 x 4.7 x 1.7cm / 1.77 x 1.85 x 0.67in Relationship,Linearity: 100Hz to 1V 0.5Khz to 5V 1Khz to 10V
Package List: 1 x Converter Module
Note: 1. The multi-turn potentiometer on the board is used to calibrate the corresponding relationship between frequency and voltage. 2. The input power supply voltage range is 12-30VDC. It is recommended that the power supply voltage be 15-24VDC. When the 12V level is used, the power supply cannot be powered by 12VDC. At least 15VDC power supply is required. If you need to use 12V power supply, you can also order 12VDC. Power converter. At 24 levels, the power supply needs to be powered by 24VDC 3. The input end is isolated by diaphragm. Guaranteed anti-interference ability. 4. If you need to use PLC, support NPN type. Must have a ground wire. 5, if you need to use the encoder, the encoder is required to continue to rotate at a constant speed for more than 0.5 seconds. 6, frequency and voltage conversion module, response time is about 0.3-0.5 seconds. 7. If the input is , etc., due to matching, an 817 diaphragm and a resistor must be added to match the flowmeter to normal function. 8. Correspondence in use If there is a deviation, you can adjust the blue potentiometer on the board to calibrate. At the time of shipment, we have adjusted the F/v potentiometer to a certain correspondence. It is generally not recommended to adjust it by itself.