Specification Brand : Garosa BulletPoint1 : [Stable Output] Provides a stable output current of 5MA for reliable performance. BulletPoint2 : [Multiple Applications] Suitable for converting interface between PLC and frequency, or movement control card and converter interface matching control . BulletPoint3 : [] Offers a quick response time of about 0.3-0.5 seconds for efficient . BulletPoint4 : [ Frequency to Voltage Module] Convert the 0-200Hz frequency pulse into a analog voltage of 0-5V. BulletPoint5 : [Versatile Input] Accommodates 5V 12V 24V input pulse levels with no need for a string resistor. However, the input frequency should be maintained for more than 0.5 seconds. ItemName : 200Hz 5V Frequency to Voltage Module, Converts 0 to 200Hz Frequency Pulse to 0 to 5V Analog Voltage, PLC Interface Converter ItemPackageDimensions_Height : 3 centimeters ItemPackageDimensions_Length : 12 centimeters ItemPackageDimensions_Width : 9 centimeters ItemTypeKeyword : frequency-transducers Manufacturer : Garosa ModelName : Garosad6o9eva15m ModelNumber : Garosad6o9eva15m NumberOfItems : 1 PartNumber : Garosad6o9eva15m ProductDescription : Specification: Condition: Brand New Item Type: Frequency To Voltage Conversion Module Model: FV-200Hz5V Function: Input 0-200Hz frequency is converted to 0-5V Output Current: 5MA Response Time: 0.3-0.5 seconds Size: Approx. 4.5 x 4.7 x 1.7cm / 1.8 x 1.9 x 0.7in
Package List: 1 x Frequency To Voltage Conversion Module
Precautions for use: 1. The multi-turn potentiometer on the board is used to calibrate the corresponding relationship between frequency and voltage. 2. The input power supply voltage range is 12-30VDC. It is recommended that the power supply voltage be 15-24VDC. When the 12V level is used, the power supply cannot be powered by 12VDC. At least 15VDC power supply is required. If you need to use 12V power supply, you can also order 12VDC. Powered converter. At 24 levels, the power supply needs to be powered by 24VDC 3. The input is isolated by diaphragm. Guaranteed anti-interference ability. 4. For use with PLC, support NPN type. Must have a ground wire. 5. If you need to use an encoder, the encoder should be rotated at a constant speed for more than 0.5 seconds. 6. Frequency and voltage conversion module, response time is about 0.3-0.5 seconds. 7. If the input isflow, etc., due to matching, an 817 diaphragm and a resistor must be added to match the flowmeter to normal function. 8. When using the correspondence, if there is a deviation, you can adjust the blue potentiometer on the board to adjust. At the time of shipment, we have adjusted the F/V potentiometer to a certain correspondence. It is generally not recommended to adjust it by itself.
ProductSiteLaunchDate : 2024-02-05T17:36:59.846Z UnspscCode : 26111700 WarrantyDescription : Manufacturer warranty for 90 day