Specification Brand : PXRZXBICQ BulletPoint : Amplifiers / Instrumentation BulletPoint1 : Relay BulletPoint2 : JDM9-4 JDM9-6 4/6-digit Digital Counter Relay Accumulation Power Outage Memory Reset PNP Sensor DC24V AC220V AC380V Color : JDM9-6 AC380V ExternallyAssignedProductIdentifier : 7320467820472 ItemName : JDM9-4 JDM9-6 4/6-digit Digital Counter Relay Accumulation Power Outage Memory Reset PNP Sensor DC24V AC220V AC380V(JDM9-6 AC380V) ItemPackageDimensions_Height : 1 centimeters ItemPackageDimensions_Length : 3 centimeters ItemPackageDimensions_Width : 2 centimeters ItemPackageQuantity : 1 ItemTypeKeyword : frequency-counters Manufacturer : PXRZXBICQ ModelName : PXRZXBICQ ModelNumber : PXRZXBICQ NumberOfItems : 1 PartNumber : PXRZXBICQ ProductDescription : Relay Counter if sensor counting is used, Sensor (photoelectric switch or proximity switch) with the model specifications for PNP, DC 6V ~ 36V.Please contact customer service if you need a switch Model: JDM9-4 / JDM9-6 Counting digits: 4 digits / 6 digits Counting range: 1~9999 1~999999 Preset method: dial switch Counting method: add/subtract counting Counting signal: contact signal/pulse voltage signal (sensor) Counting speed: 30 times/second 30CPS Contact capacity: AC220V 5A (resistive load) Mechanical life: 1 × 10 Rated voltage: DC24V, AC220V, AC380V Overall dimensions: 78 × 78× 126mm Opening size: 71 × 71mm
Instructions for use: The allowable fluctuation range of power supply voltage of 7.1 counter is 85% ~ 110% of the rated value, and the peak ripple coefficient of DC voltage is not more than 5%. If the count signal is input, the device with good contact reliability should be selected; the width of the pulse voltage signal should be greater than or equal to 10ms. Duty ratio 1: 1, voltage range 5V ~ 30V. The counter should be turned on or " reset " 50ms after the input count signal, otherwise the count may be unstable, The duration of the external reset signal should be greater than 50 ms. In the counting process, should not toggle the counter finger wheel switch, if you want to reset the number, you should first reset the counter. Counter Counting Signal and Reset Signal Input Connection Line should use double shield line, The shielding layer should be grounded at the signal input near the counter, and the connecting wire should not be too long. Counter should avoid sharing a power cord with motor, electromagnet and other large inductive load. counter if sensor counting is used, Sensor (photoelectric switch or proximity switch) with the model specifications for PNP, DC 6V ~ 36V. ProductSiteLaunchDate : 2024-05-25T09:48:31.119Z Size : One Size UnitCount : 1