Specification AgeRangeDescription : adult Brand : Rooyar BulletPoint1 : When appears normal rate but the meter does not count, when the DISPLAY button is pressed, the meter is turned this for case, the possible cause is: 1. the is or damaged; BulletPoint2 : The sealant is wrapped around the Solution: Remove the meter and that the rotates freely. BulletPoint3 : When occurs the rate is reduced and the meter does not count when the DISPLAY button is pressed, the meter is turned on. BulletPoint4 : 1. The meter is partially blocked by the dried liquid; 2. Below the minimum rate; Corresponding solution: remove the instrument to that the rotates freely; 2. Increase the rate BulletPoint5 : When the meter is not working properly, may be due to a board failure or a button failure. The corresponding solution: replace board Color : Without Display ExternallyAssignedProductIdentifier : 7661570247009 ItemName : Meter Module Digital Meter Water Meter Digital For Flowmeter Liquid Meter Use Dura ItemPackageDimensions_Height : 1 centimeters ItemPackageDimensions_Length : 3 centimeters ItemPackageDimensions_Width : 2 centimeters ItemPackageQuantity : 1 ItemTypeKeyword : science-lab-flowmeters Manufacturer : Rooyar ModelName : FKYOVUDQ ModelNumber : FKYOVUDQ NumberOfBoxes : 1 NumberOfItems : 1 PartNumber : Rooyar ProductDescription : Meter Module Digital Meter Water Meter Digital For Flowmeter Liquid Meter Use Dura
Feature: *When it appears normal rate but the meter does not count, when the DISPLAY button is pressed, the meter is turned on. In this for case, the possible cause is: 1. the impeller is stuck or damaged; 2. the sealant is wrapped around the impeller; Solution: Remove the meter and that the impeller rotates freely.
*When it occurs the rate is reduced and the meter does not count when the DISPLAY button is pressed, the meter is turned on. In this for case, the reasons may be caused by: 1. The meter is partially blocked by the dried liquid; 2. Below the minimum rate; Corresponding solution: remove the instrument to that the impeller rotates freely; 2. Increase the rate
* When the meter is not working properly, it may be due to a board failure or a button failure. The corresponding solution: replace the circuit board
Specification:
Operating 2.3-3.3V
Battery type: 2 x LRO3 batteries
Thread size: 1inch NPT
Measure accuracy: ±1
working pressure: 20BAR
15-120L / Min
Single count: 0.00-9999.9
Total cumulative count: 0-99999
Working temperature: -10°C ~ +60°C(14°F~140°F)
Standby time: 1 year
Note: And due to the difference between different monitors, the picture may not reflect the actual color of the item. Thank you!
Package Includes:
1PC x Meter ProductSiteLaunchDate : 2024-10-07T08:22:59.000Z Size : 1 UnitCount : 1 UnspscCode : 27000000