Specification Brand : Generic BulletPoint1 : Low fixed ultrasonic flowmeter with large planning integrated circuits CPLD, table process, accuracy is higher. BulletPoint2 : Low overcame a signal to a small amount of sediment, suspended particles and bubbles, the effect of improved flow measurement accuracy, especially suitable for pipe flow measurement. BulletPoint3 : Low effectively overcome the wall of the ultrasonic signal attenuation and rough surface of the pipe to scattering of ultrasonic signal from surface reduce the energy consumption of ultrasonic signal. BulletPoint4 : Day, month and year flow accumulation function, can record run 64 days before the operation, the first 64 months, the first five years of accumulated flow operation. BulletPoint5 : On low, the power management function, can record, electricity and traffic on 64 times before, can be manually or automatically compensate to reduce flow losses. Color : DN80 ItemName : Flow Control Meter TDS-100F Water Flowmeter with M2 (DN50~DN700mm, 0-160℃) Transducer Sensor, Handheld Digital Liquid Ultrasonic Flow Meter Used in Petroleum,Food, Etc. ItemTypeKeyword : science-lab-flowmeters Manufacturer : Generic MetalType : A PartNumber : VfbmRC4RciHNqAdk Pattern : Solid ProductDescription : TDS-100F Water Flowmeter With M2 (DN50~DN700mm, 0-160) Transducer Sensor Handheld Digital Liquid Ultrasonic Flow Meter Description: Is stationary time difference ultrasonic flowmeter flow body could be water, sea water, or oil, uniform liquid slurry, conduct electricity or not, corrosive or no corrosive liquid can be measured. Widely used in industrial field of various liquid flow metering online, which host is divided into standard wall hanging type, plate type, hanging type explosion-proof, the use of different field in order to meet user needs. When using a dedicated open hole tool that sensor in the zone without water supply installation, belt roller disassembly, installation method, does not affect the normal production, at any time to complete the on-line replacement and maintenance. Specifications: Linearity Better than ±1%. Accuracy ±1%ofreadingatrates>0.6 ft/s (0.2m/s). Assume a fully developed flow profile. Repeatability ±0.2%. Velocity ±0.03 ~ ±105 ft/s (±0.01 ~ ±30 m/s), bi-directional Measurement Period 0.5s Display LCD with backlight. 2x20 letters. Keypad 4x4-key membrane keypad with tactile feedback Units English (U.S.) or metric. Outputs Analogue output: 4-20mA or 0-20mA current output. Impedance 0~1kW. Accuracy 0.1%. . Isolated OCT output: for frequency output (0~9,999Hz), alarm driver, or totaliser pulse output, ON/OFF control, etc. Relay output 1A@125VAC or 2A@30VDC. For ON/OFF control, alarm driver, totaliser output, etc. Internal Alarm (Buzzer): user programmable. External Alarm Driver: alarm signal can be transmitted to Relay or OCT output terminals to drive an external alarm. RS-232 serial port. Input Five channel 4-20mA current inputs for signals such as temperature, pressure, liquid level, and etc.. Accuracy 0.1%. Two of the five input channels are wired to terminal blocks. The remaining three channels are o ProductSiteLaunchDate : 2024-09-29T09:54:35.681Z Size : 1 UnspscCode : 53000000