Product Information


Specification
AgeRangeDescription : adult
Brand : XIXIAOWU
BulletPoint : Valves
BulletPoint1 : 1, the main advantages of the sight glass is accurate, reliable, easy to use, no energy or power supply.
BulletPoint2 : 2、Sight glass can be installed inside the pipeline without dismantling the pipeline, which is convenient for maintenance and repair.
BulletPoint3 : 3、Cleaning treatment. Before use, you can use the appropriate amount of alcohol cotton in its surface lightly wiped, note: do not use acidic liquids for cleaning, so as not to corrode the outer surface of the glass.
BulletPoint4 : 4, the sight glass of the sight glass belongs to the desirable damage parts, the installation of the sight glass should be carefully and gently
BulletPoint5 : 5, and the metal should be gasket between, in order to seal, shockproof.
Color : One Color
ExternallyAssignedProductIdentifier : 7320465910854
ExternallyAssignedProductIdentifier1 : 0198462822688
ExternallyAssignedProductIdentifier2 : 198462822688
ItemName : Digital Display G1/2 Liquid Fuel Oil Flow Sensor Water Oil Liquid Meter flowmeter totameter Quantitative Controller
ItemPackageDimensions_Height : 1 centimeters
ItemPackageDimensions_Length : 3 centimeters
ItemPackageDimensions_Width : 2 centimeters
ItemPackageQuantity : 1
ItemTypeKeyword : science-lab-flowmeters
Manufacturer : XIXIAOWU
ModelName : XIXIAOWU
ModelNumber : XIXIAOWU
NumberOfBoxes : 1
NumberOfItems : 1
PartNumber : XIXIAOWU
ProductDescription : Valves
RM1307731646900015
Electrical parameters
Operating voltage range: DC24V±8V / 1A
Solenoid valve operating voltage: DC12V / 0.3A-0.5A
(Normally closed solenoid valve ,Not Include the solenoid valve )
Flow probe voltage:DC5V(Flow probe input pulse signal)
Quantitative range: 0.1-9999 l / gallon, K value can be placed in the instrument constant maximum 1-9999 l / min, gallons per minute
,Circuit connection instructions
The system has "power", "flow meter signal", "solenoid valve control", "temperature probe", and other terminal interface, the interface is connected as follows:
button
The system has six buttons: "menu key", "set key", "+ key", "- key", "start / stop key", "clear key".
a) menu:Press the "menu key" to switch the query: quantitative set value real-time value, the total flow value, K value of the flow measurement parameters and parameters to confirm. (The corresponding status display will appear);
b)Set key:Set the parameters;
c)+ key:Set the numeric value +;
d) - key: set the numeric value -;
e) Start / stop key: Run and pause operation;
f) clear key: clear operation;
g) Hold down the "Set key set" and "+" toggle the liters and gallons at the same time.
,function and parameter setting instructions
1. Quantitative settings and real-time values;
Figure 1, quantitative settings or real-time value for the system default display interface;
A,Power, the upper left corner of the LCD screen shows the temperature of the liquid out of the liquid; the upper right corner shows the user set value; the middle shows the real-time flow value, the disease saved the latest operation only; the lower left corner shows the flow state, the lower right corner shows the corresponding current Of the setting state (the current setting status can be displayed in
ProductSiteLaunchDate : 2024-09-05T13:54:51.788Z
Size : One Size
UnitCount : 1
UnspscCode : 52140000

Questions & Answers

Have a question? Ask experts

?
No question found

Ratings & Review

Rating Breakdown (average)

5*
0
4*
0
3*
0
2*
0
1*
0

No reviews found.

Have an opinion on this page? Let's hear it.