Specification Brand : Oiyagai BulletPoint1 : Can set high or low level trigger with jumper, to meet the demand of more trigger applications. BulletPoint2 : With patch optical isolation, strong drive ability and stable performance, the trigger current is 5mA. BulletPoint3 : With Fault Tolerant Design, humanized terminals, even if the control line is broken, the relay will not take any action. BulletPoint4 : With green power light, red relay status indicator light, can directly reflect the current module working condition. BulletPoint5 : Input voltage is 12V, the max load of interface is AC 250V/10, DC 30V/10A. Color : 12V CurrentRating : 10 amps ExternallyAssignedProductIdentifier1 : 765470383007 ExternallyAssignedProductIdentifier2 : 0765470383007 ItemName : Oiyagai 2pcs 12V 2 Channel High/Low Level Trigger with Optical Isolation Relay Module Fault Tolerant Design Load AC 250V/10A DC 30V/10A Circuit Switch Board ItemPackageDimensions_Height : 1 inches ItemPackageDimensions_Length : 5 inches ItemPackageDimensions_Width : 4 inches ItemPackageQuantity : 1 ItemTypeKeyword : electromechanical-relays Manufacturer : Oiyagai Material : Copper MaximumSwitchingCurrent : 10 amps MaximumSwitchingVoltage : 250 volts MeasurementSystem : Metric MeasurementSystem1 : Imperial MeasurementSystem2 : Metric ModelNumber : s16071200am0168 MountingType : din_rail NationalStockNumber : 5945-01-610-6634 NumberOfItems : 2 OperationMode : Automatic PartNumber : Oiyagai ProductDescription : Feature: Module Size: 50*41*18.5mm With 4 fixed bolt holes, diameter 3.1mm, spacing 44.5*35.5mm
High and low level trigger selection: 1. S1 1 way relay high or low level trigger selection; 2. S2 2 way relay high or low level trigger selection; 3. com and low in short circuit, the relay is low level trigger, com and high end in short circuit, the relay is high level trigger.
Input Interface: 1. DC+: to connect the power positive 2. DC-: to connect the power negative 3. IN1: 1 way signal trigger end, can set the high or low level control relay 4. IN2: 2 way signal trigger end, can set the high or low level control relay
Output Interface: 1. NO1: 1 way relay normally open interface, suspend the relay before pulling, then short connect with COM1 2. COM1:1 way relay common interface 3. NC1: 1 way relay normally close interface, short connect the relay with COM1 before pulling, then suspend 4. NO2: 2 way relay normally open relay interface, suspend the relay before pulling, then short connect with COM2 5. COM2: 2 way relay common interface 6. NC2: 2 way relay normally close interface, short connect the relay with COM2 before pulling, then suspend