Replacement BNC Electrode Probe Connector For Monitor Controller Tester Meter Kit For Hydroponics Pool Monitor For Water Hydroponics

Imported from USA | Ships in 10 working days

5% instant discount on non COD

1

₹ 3200/-

The price at cart2india.com is inclusive of custom duties, GST, freight forwarding and other charges.

Free Shipping across India. Powered by BlueDart

Product Information


Specification
Brand : LOXGO
BulletPoint1 : The external reference solution will be consumed after a period of use of the liquid-filled composite electrode. When the height of the solution in the tube is lower than the half height of the outer tube, the external reference solution in the vial in the electrode packaging box should be filled with a into the liquid filling hole.
BulletPoint2 : Observe whether the inside of the sensitive bulb is completely filled with liquid. If any bubbles are found, the measuring end of the electrode should be gently shaken down to remove the bubbles in the sensitive bulb.
BulletPoint3 : The external reference solution must be specified on the label of the vial. If the incorrect solution is added, the electrode will be damaged and cannot be used. The electrode damaged due to the wrong solution is not guaranteed.
BulletPoint4 : Before the test, remove the protective soaking bottle rubber sleeve with soaking solution on the electrode, immerse the measuring end of the electrode in distilled water, stir and clean, then take out the electrode, and dry the residual distilled water with filter paper.
BulletPoint5 : For the liquid-filling composite electrode, the small plug of the liquid-filling hole should be removed, and the liquid-filling hole should be measured in the open which will help to further speed up the response speed and test accuracy of the electrode.
Color : 3000mm length
ControllerType : Push Button
ExternallyAssignedProductIdentifier : 7622766684275
IncludedComponents : 1.5″ Uncoded Standard Hollow Cathode Lamp, Magnesium, 2 Pin, Single element.
ItemName : Replacement BNC Electrode Probe Connector For Monitor Controller Tester Meter Kit For Hydroponics Pool Monitor For Water Hydroponics
ItemPackageDimensions_Height : 3 centimeters
ItemPackageDimensions_Length : 18 centimeters
ItemPackageDimensions_Width : 5 centimeters
ItemTypeKeyword : lab-electrodes
Manufacturer : LOXGO
ModelNumber : Fybidai1uyca4evf
NumberOfItems : 1
PartNumber : LOXGO
ProductDescription : Replacement BNC Electrode Probe Connector for Monitor Controller Tester Meter Kit for Hydroponics Pool monitor for water hydroponics
Features:
Before the test, remove the protective soaking bottle rubber sleeve with soaking solution on the electrode, immerse the measuring end of the electrode in distilled water, stir and clean, then take out the electrode, and dry the residual distilled water with filter paper.
Observe whether the inside of the sensitive bulb is completely filled with liquid. If any bubbles are found, the measuring end of the electrode should be gently shaken down to remove the bubbles in the sensitive bulb.
For the liquid-filling composite electrode, the small plug of the liquid-filling hole should be removed, and the liquid-filling hole should be measured in the open which will help to further speed up the response speed and test accuracy of the electrode.
The external reference solution will be consumed after a period of use of the liquid-filled composite electrode. When the height of the solution in the tube is lower than the half height of the outer tube, the external reference solution in the vial in the electrode packaging box should be filled with a into the liquid filling hole.
The external reference solution must be specified on the label of the vial. If the incorrect solution is added, the electrode will be damaged and cannot be used. The electrode damaged due to the wrong solution is not guaranteed.

Specifications:

Bare Metal Electrode: Approx.14.7x2.5cm/ 5.75x0.98in
Cable Length: Approx.1m/39.37in
Scope of application
1. Measuring range 0-14pH (No. 8 material) 0-12pH (No. 2 material)
1. potential value 7±0.25pH (15mV)
2. Slope ≥95%
3. Internal resistance ≤250MΩ
4. Alkali error 0.2pH(1mol/L Na+ pH14)(25℃)
5. Response for time ≤10 seconds (reaching 95% of the end value,after stirring)

Packag
ProductDescription1 : 1.5″ Uncoded Standard Hollow Cathode Lamp, Magnesium, 2 Pin, Single element.
ProductDescription2 : Each regular element lamp carries a 5000 mA-Hour warranty (such as Ca, Cu, MG, Ni, etc)
ProductDescription3 : Each volatile element lamp carries a 3000 mA-Hour warranty (such as As, Bi, Cd, Sb, Se, Pb, etc).
ProductDescription4 : Warranty against manufacturing defect.
ProductSiteLaunchDate : 2024-05-17T07:48:40.000Z
SupplierDeclaredDgHzRegulation : waste
SupplierDeclaredHasProductIdentifierExemption : 1

Questions & Answers

Have a question? Ask experts

?
No question found

Ratings & Review

Rating Breakdown (average)

5*
0
4*
0
3*
0
2*
0
1*
0

No reviews found.

Have an opinion on this page? Let's hear it.