Specification Brand : IWOMA BulletPoint1 : The external reference solution will be consumed after a period of use of the liquid-filled composite electrode. When the height of the solution in the tube is lower than the half height of the outer tube, the external reference solution in the vial in the electrode packaging box should be filled with a into the liquid filling hole. BulletPoint2 : Observe whether the inside of the sensitive bulb is completely filled with liquid. If any bubbles are found, the measuring end of the electrode should be gently shaken down to remove the bubbles in the sensitive bulb. BulletPoint3 : For the liquid-filling composite electrode, the small plug of the liquid-filling hole should be removed, and the liquid-filling hole should be measured in the open which will help to further speed up the response speed and test accuracy of the electrode. BulletPoint4 : Before the test, remove the protective soaking bottle or rubber sleeve with soaking solution on the electrode, immerse the measuring end of the electrode in distilled water, stir and clean, then take out the electrode, and dry the residual distilled water with filter paper. BulletPoint5 : The external reference solution must be specified on the label of the vial. If the incorrect solution is added, the electrode will be damaged and cannot be used. The electrode damaged due to the wrong solution is not guaranteed. ExternallyAssignedProductIdentifier : 7627590424295 ExternallyAssignedProductIdentifier1 : 0843798198685 ExternallyAssignedProductIdentifier2 : 843798198685 ItemName : Replacement BNC Electrode Probe Connector Cable Sensor For Monitor Controller Tester Meter Kit For Hydroponics Pool Monitor For Water Hydroponics ItemPackageDimensions_Height : 9 centimeters ItemPackageDimensions_Length : 23 centimeters ItemPackageDimensions_Width : 10 centimeters ItemPackageQuantity : 1 ItemTypeKeyword : lab-electrodes Manufacturer : IWOMA MaximumSwitchingVoltage : 115 volts ModelName : Yosoornmiay8kz6 ModelNumber : Yosoornmiay8kz6 NumberOfBoxes : 1 NumberOfItems : 1 OperationMode : Automatic PartNumber : IWOMA ProductDescription : Replacement BNC Electrode Probe Connector Cable Sensor for Monitor Controller Tester Meter Kit for Hydroponics Pool monitor for water hydroponics Features: Before the test, remove the protective soaking bottle or rubber sleeve with soaking solution on the electrode, immerse the measuring end of the electrode in distilled water, stir and clean, then take out the electrode, and dry the residual distilled water with filter paper. Observe whether the inside of the sensitive bulb is completely filled with liquid. If any bubbles are found, the measuring end of the electrode should be gently shaken down to remove the bubbles in the sensitive bulb. For the liquid-filling composite electrode, the small plug of the liquid-filling hole should be removed, and the liquid-filling hole should be measured in the open which will help to further speed up the response speed and test accuracy of the electrode. The external reference solution will be consumed after a period of use of the liquid-filled composite electrode. When the height of the solution in the tube is lower than the half height of the outer tube, the external reference solution in the vial in the electrode packaging box should be filled with a into the liquid filling hole. The external reference solution must be specified on the label of the vial. If the incorrect solution is added, the electrode will be damaged and cannot be used. The electrode damaged due to the wrong solution is not guaranteed.
Specifications: Material: Bare Metal Electrode: Approx.14.7x2.5cm/ 5.75x0.98in Cable Length: Approx.1m/39.37in Scope of application 1. Measuring range 0-14pH (No. 8 material) 0-12pH (No. 2 material) 1. potential value 7±0.25pH (15mV) 2. Slope ≥95% 3. Internal resistance ≤250MΩ 4. Alkali error 0.2pH(1mol/L Na+ pH14)(25℃) 5. Response for time ≤10 seconds (reaching 95% of the end value,after stirring)
Packag ProductSiteLaunchDate : 2024-05-28T10:45:56.000Z Size : 10 x 15 mm SupplierDeclaredDgHzRegulation : not_applicable Voltage : 115 volts