PURPLELILY Replacement Probe Aquarium Hydroponic Laboratory Electrode Oxidation-Reduction Potential Test PH-301 BNC Connector Monitor For Water Hydroponics

Imported from USA | Ships in 10 working days

5% instant discount on non COD

1

₹ 3100/-

The price at cart2india.com is inclusive of custom duties, GST, freight forwarding and other charges.

Free Shipping across India. Powered by BlueDart

Product Information


Specification
Brand : PURPLELILY
BulletPoint : Customizable: Conventional stack with epoxy fiberglass end plate and temperature sensor.
BulletPoint1 : Before the test, remove the protective soaking bottle rubber sleeve with soaking solution on the electrode, immerse the measuring end of the electrode in distilled water, stir and clean, then take out the electrode, and dry the residual distilled water with filter paper.
BulletPoint2 : The external reference solution must be specified on the label of the vial. If the incorrect solution is added, the electrode will be damaged and cannot be used. The electrode damaged due to the wrong solution is not guaranteed.
BulletPoint3 : For the liquid-filling composite electrode, the small plug of the liquid-filling hole should be removed, and the liquid-filling hole should be measured in the open which will help to further speed up the response speed and test accuracy of the electrode.
BulletPoint4 : The external reference solution will be consumed after a period of use of the liquid-filled composite electrode. When the height of the solution in the tube is lower than the half height of the outer tube, the external reference solution in the vial in the electrode packaging box should be filled with a into the liquid filling hole.
BulletPoint5 : Observe whether the inside of the sensitive bulb is completely filled with liquid. If any bubbles are found, the measuring end of the electrode should be gently shaken down to remove the bubbles in the sensitive bulb.
ExternallyAssignedProductIdentifier : 7629661159501
ExternallyAssignedProductIdentifier1 : 0619035096546
ExternallyAssignedProductIdentifier2 : 619035096546
IncludedComponents : Other
ItemName : PURPLELILY Replacement Probe Aquarium Hydroponic Laboratory Electrode Oxidation-Reduction Potential Test PH-301 BNC Connector Monitor For Water Hydroponics
ItemPackageQuantity : 1
ItemTypeKeyword : lab-electrodes
Manufacturer : PURPLELILY
Material : Plastic
ModelNumber : AWE4AC-5cell
NumberOfItems : 1
PartNumber : PURPLELILY
ProductDescription : Replacement Probe Aquarium Hydroponic Laboratory Electrode Oxidation-Reduction Potential Test PH-301 BNC Connector monitor for water hydroponicsFeatures:Before the test, remove the protective soaking bottle rubber sleeve with soaking solution on the electrode, immerse the measuring end of the electrode in distilled water, stir and clean, then take out the electrode, and dry the residual distilled water with filter paper.Observe whether the inside of the sensitive bulb is completely filled with liquid. If any bubbles are found, the measuring end of the electrode should be gently shaken down to remove the bubbles in the sensitive bulb.For the liquid-filling composite electrode, the small plug of the liquid-filling hole should be removed, and the liquid-filling hole should be measured in the open which will help to further speed up the response speed and test accuracy of the electrode.The external reference solution will be consumed after a period of use of the liquid-filled composite electrode. When the height of the solution in the tube is lower than the half height of the outer tube, the external reference solution in the vial in the electrode packaging box should be filled with a into the liquid filling hole.The external reference solution must be specified on the label of the vial. If the incorrect solution is added, the electrode will be damaged and cannot be used. The electrode damaged due to the wrong solution is not guaranteed.Specifications:Bare Metal Electrode: Approx.14.7x2.5cm/ 5.75x0.98inCable Length: Approx.1m/39.37inScope of application1. Measuring range 0-14pH (No. 8 material) 0-12pH (No. 2 material)1. potential value 70.25pH (15mV)2. Slope 95%3. Internal resistance 250MΩ4. Alkali error 0.2pH(1mol/L Na+ pH14)(25℃)5. Response for time 10 seconds (reaching 95% of the end value,after stirring)Package In
ProductSiteLaunchDate : 2024-05-10T07:14:53.093Z
Size : 15cm
SupplierDeclaredDgHzRegulation : other
SupplierDeclaredHasProductIdentifierExemption : 1
UnitCount : 1

Questions & Answers

Have a question? Ask experts

?
No question found

Ratings & Review

Rating Breakdown (average)

5*
0
4*
0
3*
0
2*
0
1*
0

No reviews found.

Have an opinion on this page? Let's hear it.