Specification AgeRangeDescription : adult Brand : sujeniir BulletPoint : DC Contactor BulletPoint1 : Product Description: BulletPoint2 : Calomel electrode diameter 6mm, salt bridge diameter 10mm, BulletPoint3 : Classification: BulletPoint4 : 1. R232 saturated calomel reference electrode BulletPoint5 : 2, R232 saturated calomel reference electrode with 10mm salt bridge Color : Indigo ExternallyAssignedProductIdentifier : 4083928404613 ItemName : sujeniir R232 Saturated Calomel Reference Electrode, Salt Bridge for Electrolysis Experiment.(Indigo) ItemPackageDimensions_Height : 1 centimeters ItemPackageDimensions_Length : 3 centimeters ItemPackageDimensions_Width : 2 centimeters ItemPackageQuantity : 1 ItemTypeKeyword : science-lab-electrochemistry-accessories Manufacturer : sujeniir ModelName : sujeniir23905 ModelNumber : sujeniir23905 NumberOfBoxes : 1 NumberOfItems : 1 PartNumber : sujeniir23905 ProductDescription : Instructions for calomel electrode: 1. When using calomel electrode, the rubber caps on the side and end should be removed first, so that the salt bridge solution can pass through the measured solution with a certain velocity of gravity dimension. 2. There should be no bubbles in the potassium chloride solution inside the electrode, and a few potassium chloride crystals should be retained in the solution. 3. During measurement, the salt bridge solution level of calomel electrode should be slightly higher than the tested solution level to prevent the tested solution from back diffusion to the calomel electrode. 4. Because the electrode potential of calomel electrode has a large negative temperature coefficient and thermal hysteresis, temperature fluctuation should be prevented during measurement. Accurate measurement should be constant temperature. 5. If the measured solution is found to stain the collaterals of calomel electrode liquid, scale should be scraped off at any time. 6. Calomel electrode is generally not suitable for use in an environment above 70. 7. When the electrode surface with potassium chloride solution and crystals, should be removed at any time. 8. Potential changes caused by calomel electrode photolysis should be avoided from light when using and storing. 9. Double salt-bridge saturated calomel electrode (type 217) with outer casing can be used as general saturated calomel electrode if the outer casing is removed. When determining samples susceptible to K or Cl_ interference, fill the outer tube with an appropriate solution. For example: when measuring K with potassium electrode, charge 0.1mliAC; 0.1MKNO3 was charged when the chlorine electrode was used to measure Cl_. When measuring S2 - with sulfur electrode, charge 1MKNO3; And so on. ========== Is Smart Device : YES Model Number : R23 ProductSiteLaunchDate : 2024-10-17T04:46:44.396Z Size : One Size UnitCount : 1 UnspscCode : 39121529