Specification AgeRangeDescription : adult Brand : FLUXGOONE BulletPoint1 : 1. Electrode resistance: K /2. Liquid side flow rate: 1 drop/10 minutes BulletPoint2 : R0301: (Full PTFE sheath) Diameter: 8mm; Salt bridge solution - 3.5M/KCl; Electrode potential - 0.2046V/v NHE; Working temperature: 40℃. Removable. BulletPoint3 : R0302: Glass tube diameter 3.8mm, PTFE tube diameter 6mm; Salt bridge solution - 3.5m/kcl; Electrode potential - 0.2046v/v NHE; Working temperature: 40℃. Removable. BulletPoint4 : R0303: Glass tube diameter 6.0mm, PTFE tube diameter 10mm; Salt bridge solution - 3.5m/kcl; Electrode potential - 0.2046v/v NHE; Working temperature: 60℃. Removable. BulletPoint5 : R0305: Glass tube diameter 6.0mm; Salt bridge solution saturated with potassium chloride; Electrode potential -0.2046v/vs NHE; Working temperature: 60℃. Cannot be disassembled. Color : R0303 ExternallyAssignedProductIdentifier : 3017856658849 ItemName : FLUXGOONE R218/R0305 Saturated Silver Chloride Reference Electrode R0302/R0303 Removable Ag/AgCl Silver Chloride Reference Electrode.(R0303,1pc) ItemPackageDimensions_Height : 1 centimeters ItemPackageDimensions_Length : 3 centimeters ItemPackageDimensions_Width : 2 centimeters ItemPackageQuantity : 1 ItemTypeKeyword : science-lab-electrochemistry-accessories Manufacturer : JTSF ModelName : JTSF9648 ModelNumber : JTSF9648 NumberOfBoxes : 1 NumberOfItems : 1 PartNumber : JTSF9648 ProductDescription : Note: Before using the reference electrode, please check whether there are bubbles in the glass tube. If there are bubbles, you can use shaking or fingernail flicking to drive out the gas inside. If there are crystals on the outside of the glass tube, it is normal. This crystal is the internal leakage crystal after KCl is dried. At the same time, leakage is normal. In the laboratory, if the resistance increases, it may be "When the porous ceramic is dry, the polytetrafluoroethylene sleeve can be pulled out of the glass tube, a little air can be allowed to enter the glass tube, and then the glass can be placed vertically. After flicking the bubbles in the glass tube with your fingernails, the glass can be inserted into the polytetrafluoroethylene sleeve. At the same time, the KCl solution can squeeze the porous ceramic out by pressure, thereby restoring the channel state. At the same time, when the solution inside the electrode is lost, liquid can be added in this way. In this way, the electrode resistance will decrease and the electrode can be used normally. When the electrode is not in use, it can be soaked in a saturated potassium chloride solution or covered with a protective cap and stored dry. Before the second use, please soak it in a saturated potassium chloride solution for about 2 hours to activate the electrode.
Chemicals of Very High Concern: None DIY Supplies: Electrical Origin: Mainland China ProductSiteLaunchDate : 2025-02-22T05:44:35.209Z Size : 1pc UnitCount : 1 UnspscCode : 23271800