Specification Brand : Tomotato BulletPoint1 : Lack of Phase Protection --- This relay provides dynamic and static phase loss protection. When the protected equipment is in operation or non operation, and any phase fails, the indicator light will be red and priority. BulletPoint2 : Wrong Phase Protection --- This relay also provides protection against wrong phase sequence, which may occur when the L1, L2, and L3 phases of the three-phase AC power supply are not connected correctly. BulletPoint3 : Delay Protection --- The relay has a delay protection function, allowing a delay of 1-2 seconds before the relay is released. This delay can prevent tripping caused by transient faults or other issues. BulletPoint4 : Convenient & Practical --- This relay has a power consumption of no more than 2W and does not require special motor wiring for motor protection, simplifying installation and use. BulletPoint5 : Compliance with Standards --- This relay complies with GB/T 14048.1-2000, GB14048.5-2001 eqv IEC60947-1:1999 standards. Electromagnetic compatibility complies with the measurement methods and allowable values of radio interference characteristics in GB433-1995. Color : 6-20v to 13.8v 3a ExternallyAssignedProductIdentifier : 8017262524290 ItemName : TG30S Phase Sequence Protector, 220-440V AC 3-Phase Sequence Relay Mini Voltage Sequence Relay Protector for Protector Voltage ItemPackageDimensions_Height : 4 centimeters ItemPackageDimensions_Length : 8 centimeters ItemPackageDimensions_Width : 7 centimeters ItemPackageQuantity : 1 ItemTypeKeyword : digital-to-analog-converters Manufacturer : Tomotato ModelName : Tomotatogbd27w8hk9 ModelNumber : Tomotatogbd27w8hk9 NumberOfItems : 1 PartNumber : Tomotatogbd27w8hk9 ProductDescription : Type:TG30S Meet the standard: GB/T 14048. 1-2000, GB14048.5-2001 eqv IEC60947-1:199
Package list: 1 * Phase Sequence Protector
Note: The current product color can remove from the photo due to light. There may be a slight deviation in the me. Output status: One. L1, L2, L3 three-phase wiring is correct, the monitor green wood is on, the relay is closed; If the phase sequence is wrong, the monitor yellow wort is on, just exchange any two phases of L1, L2, L3 Three Passes, The monitor will be able to recover the phase sequence and work normally. When the protected device is working normally, The yellow wood is on, and when the relay does not pick up, it should be regarded as misconnection of the external line phase following, and the monitor has the function of preventing misconnection protection; Unknown type