HiLetgo 2pcs 5A AC Current Sensor Current Detection Sensor Relay 5V AC Current Relay Module AC Sensor AC Current Relay Switch with Over Current Protection

Imported from USA | Ships in 10 working days

5% instant discount on non COD

1

₹ 3200/-

The price at cart2india.com is inclusive of custom duties, GST, freight forwarding and other charges.

Free Shipping across India. Powered by BlueDart

Product Information


Specification
Brand : HiLetgo
BulletPoint : KTF-250MM Linear Position Sensor / LF-250MM Linear Position Transducer / Scaler / Electrical Ruler
BulletPoint1 : 5A AC Current Sensor Current Detection Sensor
BulletPoint2 : AC Current Relay Switch, 5V 12V 24V Optional
BulletPoint3 : Current detection resolution can change the parameter of resistance parameters
BulletPoint4 : Over-current signal setting critical point adjustable, the current detection range AC0.3A-5A
BulletPoint5 : Ip40 sealing
ExternallyAssignedProductIdentifier : 5053252359971
ExternallyAssignedProductIdentifier1 : 0796594723929
ExternallyAssignedProductIdentifier2 : 796594723929
Hazmat1 : LITHIUM METAL BATTERIES CONTAINED IN EQUIPMENT
Hazmat10 : CN_SmallLithiumMetalBatteryInEquipment
Hazmat11 : DE_SmallLithiumMetalBatteryInEquipment
Hazmat12 : EG_SmallLithiumMetalBatteryInEquipment
Hazmat13 : ES_SmallLithiumMetalBatteryInEquipment
Hazmat14 : FR_SmallLithiumMetalBatteryInEquipment
Hazmat15 : GB_SmallLithiumMetalBatteryInEquipment
Hazmat16 : IN_SmallLithiumMetalBatteryInEquipment
Hazmat17 : IT_SmallLithiumMetalBatteryInEquipment
Hazmat18 : JP_SmallLithiumMetalBatteryInEquipment
Hazmat19 : MX_SmallLithiumMetalBatteryInEquipment
Hazmat2 : UN3091
Hazmat20 : NL_SmallLithiumMetalBatteryInEquipment
Hazmat21 : PL_SmallLithiumMetalBatteryInEquipment
Hazmat22 : SA_SmallLithiumMetalBatteryInEquipment
Hazmat23 : SE_SmallLithiumMetalBatteryInEquipment
Hazmat24 : SG_SmallLithiumMetalBatteryInEquipment
Hazmat25 : TR_SmallLithiumMetalBatteryInEquipment
Hazmat26 : US_SmallLithiumMetalBatteryInEquipment
Hazmat27 : ZA_SmallLithiumMetalBatteryInEquipment
Hazmat3 : II
Hazmat4 : 9
Hazmat5 : AE_SmallLithiumMetalBatteryInEquipment
Hazmat6 : AU_SmallLithiumMetalBatteryInEquipment
Hazmat7 : BE_SmallLithiumMetalBatteryInEquipment
Hazmat8 : BR_SmallLithiumMetalBatteryInEquipment
Hazmat9 : CA_SmallLithiumMetalBatteryInEquipment
ItemName : HiLetgo 2pcs 5A AC Current Sensor Current Detection Sensor Relay 5V AC Current Relay Module AC Sensor AC Current Relay Switch with Over Current Protection
ItemPackageDimensions_Height : 14.3 centimeters
ItemPackageDimensions_Length : 3.5 centimeters
ItemPackageDimensions_Width : 7.9 centimeters
ItemPackageQuantity : 1
ItemTypeKeyword : electronic-component-current-sensors
Manufacturer : HiLetgo
Material : Copper
ModelNumber : 723929
NumberOfItems : 1
PartNumber : 3-01-1815-5V
ProductDescription : Specifications:
Working voltage: DC5V/12V/24V
Working current: <20mA
Frequency range: 20Hz-400Hz
Output mode: switching signal output
Humidity: 0-95% RH
Size: 4.4x3.8cm/1.73x1.5"
Interfaces:
VCC: Positive;
GND: Negative;
NO: Normally open, NO and COM are disconnected before the relay is closed, and short circuit after the relay is closed
COM: common, relay common interface;
NC: Normally closed, NC and COM are shorted before the relay is closed, and disconnected after the relay is closed
Instructions:
5A Over-current protection Sensor moduleuses current transformer to collect the AC signal to achieve the relay over-current signal output within 0-5A. Relay pull while over-current, relay released while not over-current. Users can use the relay COM, NC, NO three ports to control the external circuit on and off, in order to achieve over-current protection.
Use the potentiometer to set the overcurrent protection point, the clockwise adjustment reduces the detection current.
1. Measured the wire through the current transformer, connect VCC and GND to DC12V power supply.
2. Adjust the potentiometer, when you hear the sound of the relay pull (can be measured with a multimeter COM and NO whether was turned on, if connected to the relay means activated), then reduce or cut off the current flowing that through the tested wire , if the relay release at this time that over-current protection point has been identified (available to multimeter COM and NC measurement whether is connected, if connected to the relay means been released).
3. When reduce or cut off the current flowing through the wire , the relay is not released, will still need to continue to adjust the potentiometer to find the over-current protection point.
Package included:
2 x AC Current Sensor Relay Modules (5V 12V 24V Optional, you will get the two SAME ones, not mixed types.)
ProductSiteLaunchDate : 2023-09-07T08:16:08.584Z
StreetDate : 2017-03-29T00:00:01Z
Style : 5V
SupplierDeclaredDgHzRegulation : not_applicable
UnitCount : 1

Questions & Answers

Have a question? Ask experts

?
No question found

Ratings & Review

Rating Breakdown (average)

5*
0
4*
0
3*
0
2*
0
1*
0

No reviews found.