Lab High Speed Centrifuge Machine Bechtop Microcentrifuges 3 in 1 Rotor for 0.2/0.5/1.5/2mL Tube Capacity (12000RPM)

Imported from USA | Ships in 10 working days

5% instant discount on non COD

1

₹ 54900/-

The price at cart2india.com is inclusive of custom duties, GST, freight forwarding and other charges.

Free Shipping across India. Powered by BlueDart

Product Information


Specification
Brand : JOANLAB
BulletPoint1 : JOANLAB MC serice is perfect benchtop microcentrifuge for your lab to do quick spin downs .With over temperature protection, when the temperature in the centrifugal chamber is too high during operation, the centrifuge machine will automatically shut down and open the lid, the buzzer will alarm for 5 seconds,and the SAFE flashes. Avoid damage to temperature-sensitive experimental samples due to excessive temperature to meet your diverse experimental needs.
BulletPoint2 : Program Memory Function,The speed and time of model MC-12PRO required by experiments can be freely set,and the program can be stored,for direct use in the future.No need to reset, more conveniently;
BulletPoint3 : Equipmented with 3 in 1 Rotor , it do not need to change rotor, it is time-saving. This lab minicentriuge accept 12-position 1.5/2 mL tube as well as a 4-position 12-strip PCR tube rotor that can accommodate 48 individual PCR tubes or 0.2mL strip tubes. With the included adapters, 0.2 mL and 0.5 mL strip tubes can also be accommodated in the 12 position tube rotor, further increasing its versatility.
BulletPoint4 : SAFETY PROTECTION-low voltage power input, sturdy lid, and rotor's safety buckle design. Automatic lid lock function keeps the lid locked during the operation and releases until the machine stops, protecting the operator from being injured by the high-speed spinning rotors.
BulletPoint5 : With a quiet motor, and rubber base that absorbs vibrations,JOANLAB high speed mini centrifuge manchine keeps operational noise to a minimum , less than 56db(A) and reduces disruptions in the laboratory. And it takes simple operation to a new level. Once the device is powered on, simply place your sample in the centrifuge, close the lid, and it will begin to rotate. Not even one button press is needed in order to separate your sample.
Capacity : 100 milliliters
Color : YQ-701024
CustomerPackageType : Standard Packaging
ExternallyAssignedProductIdentifier1 : 304661112127
ExternallyAssignedProductIdentifier2 : 0304661112127
ExternallyAssignedProductIdentifier3 : 00843798149083
IncludedComponents : Centrifuge
ItemName : Lab High Speed Centrifuge Machine Bechtop Microcentrifuges 3 in 1 Rotor for 0.2/0.5/1.5/2mL Tube Capacity (12000RPM)
ItemPackageDimensions_Height : 35.814 centimeters
ItemPackageDimensions_Length : 13.716 centimeters
ItemPackageDimensions_Width : 22.352 centimeters
ItemPackageQuantity : 1
ItemTypeKeyword : science-lab-benchtop-centrifuges
Manufacturer : JOANLAB
Material : Plastic & Aluminum Alloy
ModelNumber : LXJ-LMJPQ-US001@CTDUV94
NumberOfBoxes : 1
NumberOfItems : 1
PartNumber : JCMC
ProductDescription :

Technical Data:

Speed: 4000 r/min.

Maximum Relative Centrifugal Force: 2770*g

Voltage:110V,60HZ

Fixed time: 0-60min

Capacity: 100 ml × 4 (Diameter: 36 mm, Length: 115 mm)


Packing list: 

1 x LD-4 table centrifuge 


Safety instructions:

-If the power indicator is not on when the machine is started, stop the machine for inspection immediately.

-It is forbidden to operate without load without turning head.

-Before operation, check the swivel for corrosion damage.

-Do not open the cover of the centrifuge and do not touch the rotating head when the rotating head is running.

-It is forbidden to turn the head to operate under the condition of unbalanced loading.


Instructions for use:

(1) The working table of the centrifuge shall be flat and firm, and the working room shall be clean, dry and well ventilated.

(2) Turn on the power switch and the indicator light will be on.

(3) Open the centrifugal cover, wipe the inner cavity and the rotating head clean.

(4) Put the test tube with the same weight.

(5) Set timing

(6) Turn on the power switch

(7) Adjust the speed control knob to the required speed.

(8) Before each shutdown. The speed control knob must be set to the minimum position. Set the timer to zero. Turn off the power switch again.

(9) Wipe the inner cavity and rotating head. Close the centrifugal cover.


ProductSiteLaunchDate : 2022-01-10T05:58:11.340Z
Style : MC-12pro
SupplierDeclaredDgHzRegulation : not_applicable
UnitCount : 1
Voltage : 120 volts

Questions & Answers

Have a question? Ask experts

?
No question found

Ratings & Review

Rating Breakdown (average)

5*
0
4*
0
3*
0
2*
0
1*
0

No reviews found.

Have an opinion on this page? Let's hear it.