SpecificationBrand : CRYBY
BulletPoint1 : This motorized centrifuge has two rotary knobs on the control panel for easy control of time and speed. You can set the time and speed you want by controlling the knobs.
BulletPoint2 : This motorized centrifuge is a routine centrifuge for laboratories, this instrument has the advantages of large capacity, low temperature, low noise, easy operation, safety and reliability.
BulletPoint3 : Our centrifugal machine is designed with fixed angle, the advantage of which is that there are no moving parts in the rotor, which puts less pressure on the metal and prolongs the service life.
BulletPoint4 : This benchtop centrifuge is widely used in higher education, agricultural science and technology, petrochemical, biochemical, life science, biological products, environmental protection and other major experimental teaching fields.
BulletPoint5 : The speed of this electric centrifuge is adjustable and made of high quality materials for durability.
Color : #255
ExternallyAssignedProductIdentifier : 8467694241669
ExternallyAssignedProductIdentifier1 : 0764331067582
ExternallyAssignedProductIdentifier2 : 764331067582
IncludedComponents : Electric Benchtop Centrifuge Machine
ItemName : CRYBY Electric Benchtop Centrifuge Machine, Electric Lab Laboratory Dental Centrifugal Device with Speed Control and Timer, Low Noise Desktop Centrifuge for Lab School Scientific Research, 4000r/Min
ItemTypeKeyword : science-lab-benchtop-centrifuges
Manufacturer : LOHONG
ModelName : Kimiss6c71ig9xow
ModelNumber : KIMISS6c71ig9xow
NumberOfItems : 1
PartNumber : Lh0000518
ProductDescription :
The Main Technical Indicators:
Model: Ld-3
Maximum Speed: 4000r/Min
Centrifugal Force: 2770xg
Capacity: 50ml * 6
Timing: 0-60min Special Use Requirements Should Be Explained
Attention:
1. After Working for a Period of Time, the Temperature of Sample May Rise by 5-15℃. and You’d Better Not Keep the Machine Running More than 30 Minutes at a Time.
2. Please Empty the Centrifugal Tubes Evenly Before Working, Working 1-2 Minutes at the Maximum Speed, the Begin to Work If There Is No Problem.
3. Please Clean the Tube and Rotor After Using and Put down the Cover to Avoid the Pollutant and Dirt.
4. Please Open the Cover and Dry the Tube Before You Are Going to Use When the Centrifuge Has Not Been Used for a Long Time.
5. Do Not Touch the Rotor While It Is Running.
6. Do Not Move the Machine While It Is Running.
7. Do Not Operate the Machine If the Rotor Is Not Stably Loaded.
8. Please Ask the Technician to Solve the Problem If the Wire and Plug Are Damaged or Electric Appliances Are in Trouble.
9. the Value of Rated Parameters of the Power Plug Offered by the Consumer Should Be More than That Machine and It Should Have Well Earth Connection.
ProductSiteLaunchDate : 2024-05-25T09:27:45.510Z
SupplierDeclaredDgHzRegulation : not_applicable
UnspscCode : 41000000