Details
4 Rubber Non-slip Feet: They can absorb the shock, prevent the machine from slipping, and avoid scratching the tabletop.
Heat Dissipation Holes: They ensure timely heat dissipation of the machine and prolong its service life.
Intelligent Fan: The fan with intelligent speed control function can effectively reduce the noise when working.
Application
This product can be widely used in the production line test of chargers, switching power supplies, linear power supplies, batteries, and other industries. It is an indispensable tool for power supply product development, production testing, and quality control.
Specifications
Model: ET5406A+
Style: Modern
Shape: Rectangular
Color: Black
Material: Aluminium, Silicone
Surface Treatment: Spray Painting
Plug Standard: US Standard
Mount Type: Tabletop
Assembly Required: No
Power Source: Corded Electric
Battery Tester Discharge Mode: CC, CR
Voltage: 0-120V
Input Current: 0-20A
Input Power: 200W
Operating Temperature: 0°C -40°C/ 32-104 ℉
Storage Temperature: -10℃ -70°C/ 14-158 ℉
Relative Humidity: <80 %
Maximum Discharge Capacity: 9999 Ah
Power Cord Length: 1.48m/ 4.85 FT
CV Mode
Range: 0.1~19.999V, 0.1~120.00V
Resolution: 1mV, 10mV
Accuracy: ±(0.05%+0.02%FS)
CC Mode
Range: 0~3.000A, 0~20.00A
Resolution: 1mA, 10mA
Accuracy: ± (0.05%+0.05%FS)
CR Mode
Range: 0.05Ω~4.50kΩ
Resolution: 10mΩ, 1Ω
Accuracy: ± (0.1%+0.5%FS)
CP Mode
Range: 0~200W
Resolution: 10mW
Accuracy: ± (0.1%+0.5%FS)
Gross Weight: 4.3kg/9.48 lbs
Net Weight: 1.5kg/ 3.31 lbs
Product Size: 30*14*21cm/ 11.81*5.51*8.27 in
Package Size: 41*43*61cm/ 16.14*16.93*24.01 in
Package Included
1* Electronic Load Tester
1* Power Cord
1* Communication Interface
1* Chinese Manual
Notes
1.Please note that although there is an LED icon in the Mode column of the segment code screen, this instrument does not have an LED test mode, nor does it have a battery internal resistance test.
2.Please note that there must be a positive voltage between the red and black terminals, if a negative voltage is input, there will be a reverse connection warning. Reverse connection may damage the instrument itself, or damage the power supply under test.
3.Please be careful not to input voltage to the input terminals without powering up and switching on the instrument. When the instrument is powered on, there will be a short-circuit self-test at the input terminals for 2 ms.
4.Please allow the slight color difference caused by the shooting light and 1-3cm error due to manual measurement, and make sure you do not mind before you order.