Specification Brand : DR.ONIC BulletPoint1 : Fits the vertical wall vents only BulletPoint2 : Eco-Friendly and Green Humidifier BulletPoint3 : Works without electricity BulletPoint4 : Silent operation BulletPoint5 : Very low maintenance Capacity : 95 liters Color : White ControlMethod : touch ExternallyAssignedProductIdentifier1 : 0627843312864 ExternallyAssignedProductIdentifier2 : 627843312864 ExternallyAssignedProductIdentifier3 : 757686658154 ExternallyAssignedProductIdentifier4 : 654936820296 ItemName : Digital Humidity Chamber Apparatus, Humidity Cabinet Machine, Heating & Cooling Chamber Apparatus with Automatic ON-Off Feature (110-240V) ItemPackageDimensions_Height : 10 centimeters ItemPackageDimensions_Length : 20 centimeters ItemPackageDimensions_Width : 15 centimeters ItemPackageQuantity : 1 ItemTypeKeyword : humidifier-accessories Manufacturer : Onic Enterprises Material : Polyrethane ModelNumber : Vetus MountingType : Tabletop NumberOfItems : 1 PartNumber : HTCL-852i PowerSourceType : Corded Electric ProductDescription : ISO CE Humidity Cabinet General specification as made out of stainless steel. The temperature can be controlled from 5 C to 50 C 2C and humidity from 45% to 90% 5% RH Temperature below ambient is controlled by hermetically sealed compressor complete with accessories provided below the unit. Two stainless steel water reservoirs heated by immersion heaters are provided to create humidity. Complete with all accessories. Control panel provided with control switches and indicators. The Digital Temp. controlled the temperature before 15 to 20 as the set temperature and temperature will be increase or decrease slowly and maintain it on highest point as your requirement. The Humidity controlled the humidity before 20 to 30 as the set humidity and humidity will be increase slowly and maintain it on highest point as your requirement. 2. Zero Offset Adjust - Rotate the HUM SET ADJ control to its fully counterclockwise position (0% R.H.). Adjust R6 so that the voltage measured at U2-6 is 0.000 .001 Volts. Use the + lead on C6 as a ground point. 6.1 Humidity Controller 3. Full Scale Calibration - Adjust the HUM SET ADJ control to its fully clockwise position (100.0% R.H.). Adjust R4 so that the voltage measured at U2-3 is +5.00 .01 Volts. 4. Display 100% Point Calibration - Depress the READ/SET switch and observe the Display reading. Adjust R28 so that the Display indicates 100.0% R.H. a) 455 x 455x 455 mm 95 ltrs. ProductSiteLaunchDate : 2018-04-27T07:00:00.000Z RoomType1 : Living Room RoomType2 : Bedroom Size : Medium SupplierDeclaredDgHzRegulation : not_applicable UnitCount : 1