Specification Brand : Deeoee BulletPoint : AC 85-230V 10A SHT2000 LED Digital Temperature Humidity Controller Thermoregulator thermostat Hygrometer Control 50/60Hz ExternallyAssignedProductIdentifier : 4862440197001 ItemName : AC 85-230V 10A SHT2000 LED Digital Temperature Humidity Controller Thermoregulator Thermostat Hygrometer Control 50/60Hz ItemPackageDimensions_Height : 2 centimeters ItemPackageDimensions_Length : 8 centimeters ItemPackageDimensions_Width : 7 centimeters ItemPackageQuantity : 1 ItemTypeKeyword : humidifier-accessories Manufacturer : Deeoee Material : Copper NumberOfItems : 1 PartNumber : CXXMODULE-10358 ProductDescription : Product Name: Temperature and Humidity Controller Product model: SHT2000 Supply voltage: AC 110~230V Power supply frequency: 50/60Hz Temperature range: -20~60°C Humidity measurement range: 0%~100%RH Temperature measurement accuracy: 0.3 °C Humidity measurement accuracy: 3% Output control: relay output Output power: MAX 10A Setting method: Start value <stop value (program automatically determines working mode is heating/humidifying mode) Setting method: Start value > stop value (the program automatically determines the working mode is cooling/dehumidifying mode) Heating/cooling mode setting Setting mode: setting (starting temperature): Press and hold the ▲ button to start the temperature flashing. Use ▲▼ key to set the starting temperature value. Setting (stop temperature): Press and hold the ▼ button to stop the temperature flashing. Use ▲▼ to set the stop temperature value. Heating use case: control the water heater, heat to 65 ° C to stop, the temperature drops back to 50 ° C and start heating again The first step: heating mode, starting temperature <stop temperature Step 2: Press and hold the ▲ button to start the temperature flashing. Use ▲▼ to set the starting temperature to 50 °C. Step 3: Press and hold the ▼ button to stop the temperature flashing. Set the stop temperature to 65 °C with ▲▼ keys, and the setting is completed! Refrigeration use case: use in the farm, the fan is ventilated to 26 ° C to stop, the temperature is raised to 30 ° C and the ventilation is started again. The first step: cooling mode, starting temperature > stop temperature Step 2: Press and hold the ▲ button to start the temperature flashing. Use ▲▼ to set the starting temperature to 30 °C. The third step: long press the ▼ button to stop the temperature flashing, set the stop temperature to 26 °C by ▲▼, the setting is completed! Humidifi ProductSiteLaunchDate : 2021-06-26T18:41:11.237Z